8 Timing out signal output
59
4.
Motor is move to the end point direction, and the signal is generated from the time
that has passed through the start point.
In gate mode, the signal is outputted between the start point with the end point until
releasing the output preparation state of the timing signal.
In pulse mode, the output ready status is canceled and the output pulse once. However,
the pulse is generated, if the motor has resumed to move in the same direction, until
the motor pass through the end point, even if the motor stops in the middle.
In the moving to the CW direction, If you resume the operation from
◆
in the
above figure that is stopped, the pulse is output with the solid line of Timing out
output. The dotted line area is considered that has been already outputted. And,
the pulse is not outputted, even if it has moved to the CCW direction.
If you don't want to output the pulse if it is moved to the CW direction after stop at
◆
, please cancel the output ready by "TMGCx" command. And then, pulse is not
output until the ready state to the next.
Timing signal manual output mode
If you set <type> to 6 with the command "TMGM <ch> <type>", you can output
the timing signal to the level output arbitrarily, and if you set 7 to A, you can output
1 pulse. In case of 6, H level is output by TMGR <ch> and L level is output by
TMGC <ch>.
For 7 to A, a pulse with the set width is output once each time TMGR <ch> is input.
Timing output channel fixed mode
In addition to the conventional mode (the timing signal output channels are linked
to the display position on the LCD), mode to fix the output channel is now available.
An example, If TP0 has been set to CH0, CH0's timing signal is outputted from TP0,
even if it has not been displayed on the LCD top line. And this is the feature of the
output channel fixed mode.
In local mode operation, you can change settings by "5-8 Page8 TIMING OUT
channel setting" (page 29). In remote mode operation, make the setting with the
following command.
Command TMGFX <md>
Set the output channel mode of the timing signal.
Argument <md>
Output
mode
DS/ Output from the channel in the display.
EN/ Output channel fixed mode
Reply Nothing
Example TMGFX EN
Remarks
Only remote mode, it’s effective only when the motor of all channels is stopped.
Item that is shaded is the default parameter settings at reset.
Timing out output
CCW start point
End point CW