Connections CaloSys Module - Pull Principle Respirometry - Multiple High-Speed Sensor Units
Port
Function
Calorimetry Master Control Unit1, 2
"System_1_X01"
37-pin connection to PC.
"System_1_X02"
37-pin connection to PC.
"System_1_X03"
37-pin connection to PC.
"System_1_X04"
25-pin connection to Sample Switch Unit1.
"System_1_X05"
37-pin connection to Calorimetry Slave Control Unit1.
"System_1_X07"
37-pin connection to PC.
"System_2_X01"
37-pin connection to PC.
"System_2_X02"
37-pin connection to PC.
"System_2_X03"
37-pin connection to PC.
"System_2_X04"
25-pin connection to Sample Switch Unit2.
"System_2_X05"
37-pin connection to Calorimetry Slave Control Unit2.
"System_2_X07"
37-pin connection to PC.
"Flow IN 1...8"
Tube connection to animal cage1...8.
"Flow OUT"
Tube connection to vacuum pump1 (System_1), vacuum pump2 (System_2).
"Sample IN 1...2"
Tube connection Calibration Slave Control Unit1 (System_1), Calibration Slave Control Unit3 (System_2).
"Sample OUT 1...2"
Tube connection to High-Speed Sensor Unit1 and 2 (System_1), High-Speed Sensor Unit5, and 6 (System_2).
"Ref. Air1, 3"
Tube connection to reference cage1 (System_1), reference cage3 (System_2).
"X0 ext"
Connection to Calibration Master Control Unit (Calorimetry Master Control Unit1 only).
"Temperature 1...8"
Cable connections temperature sensors.
Calorimetry Slave Process Control Unit1, 2
"Flow IN 9...16"
Tube connection to animal cage9...16.
"Flow OUT"
Tube connection to vacuum pump1 (System_1), vacuum pump2 (System_2).
"Sample IN 3...4"
Tube connection Calibration Slave Control Unit2 (System_1), Calibration Slave Control Unit4 (System_2).
"Sample OUT 3...4"
Tube connection to High-Speed Sensor Unit3 and 4 (System_1), High-Speed Sensor Unit7, and 8 (System_2).
"Ref. Air2, 4"
Tube connection to reference cage2 (System_1) reference cage4 (System_2).
"X06"
Connection to Calorimetry Master Control Unit.
"Temperature 1...8"
Cable connection temperature sensors.
Vacuum Pump1, 2
"Vac inlet"
Tube connection to Calorimetry Control Unit via pressure control valve.
Animal Cage
"Air OUT"
Tube connection to Calorimetry Control Unit, used air outlet.
"Air IN"
Inlet, fresh air supply.
"Sample"
Tube connection to Sample Switch Control Unit.
Sample Switch Control Unit1, 2
"1...4"
Tube connection for animal cage 1...4.
"Ref1"
Tube connection for reference air (reference cage 1).
"Out1
Tube connection to Air Drying Unit1.
"5...8"
Tube connection for animal cage 5...8.
"Ref2"
Tube connection for reference air (reference cage 1).
"Out2"
Tube connection to Air Drying Unit2.
"9...12"
Tube connection for animal cage 9...12.
"Ref3"
Tube connection for reference air (reference cage 2).
"Out3"
Tube connection to Air Drying Unit3.
"1...4"
Tube connection for animal cage 13...16.
"Ref4"
Tube connection for reference air (reference cage 2).
"Out4"
Tube connection to Air Drying Unit4.
"X04"
25-pin connection to Calorimetry Master Control Unit.
Air Drying Unit1...8
Sample "IN"
Tube connection to sample switch pump.
Sample "OUT"
Tube connection to Calibration Slave Control Unit via separating bottle.
Calibration Master Control Unit
"Unit IN 1...4"
3-pin connection to Calibration Slave Control Unit1...4.
"Gas OUT 1...4"
Tube connection to Calibration Slave Control Unit1...4 .
Gas Inlet 1...3
Tube connection to calibration gas cylinders1...3 via pressure regulator.
"X0 ext"
Connection to Calorimetry Master Control Unit1.
Calibration Slave Control Unit1...4
"Gas"
Tube connection to Calibration Master Control Unit.
"Unit 1...4"
3-pin connection to Calibration Master Control Unit.
"Sample IN 1...8"
Tube connection to Air Drying Unit1...8 via separating bottle.
"Sample OUT 1...8"
Tube connection to Calorimetry Control Units.
Содержание Calorimetry PhenoMaster
Страница 6: ...6 PhenoMaster Hardware Operating Instructions info TSE Systems com www TSE Systems com ...
Страница 13: ...CaloSys Modules 13 Confirm default installation path by pressing Next info TSE Systems com www TSE Systems com ...
Страница 15: ...CaloSys Modules 15 Press Finish info TSE Systems com www TSE Systems com ...
Страница 69: ...CaloSys Modules 69 info TSE Systems com www TSE Systems com ...