"inductive" (default setting)
−
"capacitive"
5. For "DC link precharge config", enter:
1
.
6. Start transmission of power.
−
User interface:
Select >
Operation
>
Device control AC-DC
.
For "Activate power stage [bit]", enter = "1".
Press key
↲
.
−
Modbus:
For the address for power operation, set bit = 1.
7. To stop the transmission of power:
−
User interface:
For "Activate power stage [bit]", enter = "0".
Press key
↲
.
−
Modbus:
For the address for power operation, set bit = 0.
8. Starting/stopping power transmission for other AC-DC mod-
ules
Ø
Select another AC-DC module (via user interface or
slave address via Modbus) and perform the previous
steps again.
or
Ø
To switch on all AC-DC modules simultaneously:
−
User interface:
For "Slave module selection" enter "0".
−
Modbus:
Enter the number of the slave to be addressed =
"0" .
Ø
Start transmission of power.
7.5
Displaying and resetting messages
User interface: displaying and resetting
messages
If a message is pending, the icon for messages
is colored
orange or red . If there are any warnings present, the icon is
orange. If at least one alarm is pending, the icon is colored red.