1
Opening for reset button
Reset button on the system control
Fig. 38
5. Insert a small pen tip or piece of wire into the opening for
the Reset button and press and hold down the Reset button
for 3 seconds.
6. Switch 24 V supply voltage off and back on again to restart
the system.
The IP address of the TruConvert System Control is reset
to: 192.168.1.2
7. To change the network settings:
−
User interface:
Enter new values for "IP Subnet Mask", "IP Host" and
"IP Gateway".
Press "Submit IP Configuration".
−
Modbus:
Enter new values for IP subnet and IP gateway .
The network settings are transferred to the system control.
7.12 Software update
Perform software update
Conditions
■
Operation via web-based user interface
■
Zip file with new software stored on PC.
1. Select >
SW update
.
2. In the "Software update" area, press the
button and
open the zip file.
3. Press the
button to upload the zip file.
If the update was performed successfully, the system control
automatically performs a restart.
66
Operation
2020-06-10
A67-0141-00.BKEN-
001-05
Changing the IP subnet and
gateway