2: DC-DC only
Only DC-DC modules are connected to the system
control.
−
3: n (AC-DC + m DC-DC)
AC/DC and DC/DC modules are connected to the sys-
tem control.
3. To save the selection: press "Save selection".
4. To restart the TruConvert System Control: press "Restart
CPU".
1
Display of the current device
status
2
Main operating parameters
(start page)
3
Device configuration (time and
network settings)
4
Software update
5
Device identification (display
only)
6
Submenu
7
Sidebar (alarm, warning and
event messages)
Start screen
Fig. 37
Status LEDs on the AC-DC module and system control: The
LEDs remain off immediately after the restart. The green
LED begins to flash after a few seconds.
The system is ready for operation: It is in "Idle" mode and
the start screen is displayed.
The system control balances the set system configuration
with the actually connected modules. If both values match,
the start screen is displayed.
If the set system configuration ("Expected configuration") dif-
fers from the automatically detected system configuration
("Detected configuration"), the input screen "System configu-
64
Operation
2020-06-10