6.8
Dismantling
Connection cables carry life threatening voltage!
Ø
Open the external mains separation device between mains
and the power connection of the device.
Ø
De-energize the cable between mains and the mains syn-
chronization connection.
Ø
De-energize the connection cables to the DC link voltage.
Ø
Maintain discharging time: at least 5 min.
1. Open external mains separation device.
2. De-energize the connection cables to the DC link voltage.
3. De-energize the connection cables to the 24 V supply volt-
age.
Dangerous residual voltage
Ø
Maintain discharging time: at least 5 min.
4. Check mains cable and DC link-voltage cable to ensure that
they are not electrically live.
5. At power connection "Mains":
−
Undo the 2 screws on the flange.
−
Disconnect mains cable.
6. At DC link connection:
−
Undo the 2 screws on the flange.
−
Disconnect the DC link cable.
7. At connection for contactor release contact and mains volt-
age measurement "Contactor / Mains Measurement":
−
Release the automatic locking mechanism.
−
Disconnect the cable for mains voltage measure-
ment / release contact.
8. 24 V supply voltage:
−
Release the automatic locking mechanism.
−
Disconnect the 24 V supply cable.
9. Disconnect data cable.
10. Unscrew and remove the equipotential bonding conductor if
necessary.
A67-0141-00.BKEN-
001-05
2020-06-10
Installation
39
WARNING
Removing residual voltages
WARNING
Unscrew or unplug cables