ration" is displayed again and a message output. Press side-
bar (7) to display the messages.
7.11 System control
Setting the system time
As soon as the device is connected to the PC, the local time of
the PC is converted to UTC and adopted in the system control
as system time.
In addition, adoption of the system time can also be triggered
manually.
1. In the sidebar, click on "Settings"
.
The sidebar is displayed.
2. To adopt the system time from the PC for the device, press
"Synchronize to local computer".
Then press "Submit time and date".
The system time of the PC is displayed on the user inter-
face and transferred to the device.
3. Enter new values for date and time .
Changing network settings
Note
The IP address can only be changed via the user interface.
1. Select >
CONFIGURATION
>
Server Configuration
.
2. Enter new values in "IP Adresse".
(IP address of the TruConvert System Control on delivery:
192.168.1.2)
3. Note the new IP address so as to be able to access the sys-
tem control via the user interface or via Modbus.
4. Press "Submit IP Configuration".
The network settings are transferred to the system control.
If the IP address of the system control was changed and is not
known, the IP address can be reset to the factory settings with
the help of the Reset button.
A67-0141-00.BKEN-
001-05
2020-06-10
Operation
65
User interface
Modbus
Changing the IP address
Using the Reset button to
reset the IP address