![Trox Technik FKR-EU Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/trox-technik/fkr-eu/fkr-eu_installation-and-operating-manual_1172495155.webp)
Item
no.
Description
4
Ceilings
4.10
Composite ceiling
4.11
Historical wooden beam ceiling, fire resist-
ance properties
≥
F 30
4.12
Panelled ceiling
Item
no.
Description
5
Fixing material
5.1
Dry wall screw
5.2
Hexagon head screws, washers, nuts (see
installation details)
5.3
Chipboard screw
5.3a
Chipboard screw 5
×
80 mm
5.3b
Chipboard screw 5
×
100 mm
5.3c
Chipboard screw 5
×
60 mm
5.3d
Chipboard screw 5
×
50 mm (4 - 8 pieces,
depending on the damper size)
5.3e
Chipboard screw 5
×
70 mm (16 - 28 pieces,
depending on the damper size)
5.4
Threaded rod, galvanised steel (see installa-
tion details)
5.5
Carriage bolt L
≤
50 mm with washer and nut
5.6
Screw or rivet, galvanised steel (see installa-
tion details)
5.7
Wallplugs with fire suitability certificate for fire
resistance
5.8
Anchor M8 – M12
5.9
Steel bracket
5.10
Fixing tab
5.11
Floor mounting plate
5.12
Cover plate
5.13
Wood screw or pin
5.14
Angle bracket
5.15
Bracket
5.16
Wall connection frame
5.17
Anchor bolt
5.18
L-bracket according to EN 10056-1 galvan-
ised, painted or similar, according to installa-
tion detail
5.19
Connecting clip
Item
no.
Description
5
Fixing material
5.20
Screw Fischer® FFS 7.5
×
82 mm or equiva-
lent
5.21
Screw / wallplug
5.22
Steel fabric,
Æ
≥
8 mm, mesh aperture
150 mm or equivalent
5.23
Clamp, e.g. Hilti MP-MX, Valraven BIS HD
500, or equivalent
5.24
Sheet-metal strip
5.25
Plasterboard screw
5.26
Steel wire clip
Item
no.
Description
6
Filling and coating material
6.1
Mineral wool
≥
1000 °C,
≥
40 kg/m³
6.2
Mineral wool
≥
1000 °C,
≥
80 kg/m³
6.3
Mineral wool
≥
1000 °C,
≥
100 kg/m³
6.4
Mineral wool
≥
1000 °C,
≥
140 kg/m³
6.5
Mineral wool (depending on wall construc-
tion) / ceiling construction, mineral wool filling
on request
6.6
6.7
Fire batt
6.8
Infill (cavities completely filled with mineral
wool
≥
1000 °C,
≥
50 kg/m³, or bricks, aer-
ated concrete, lightweight concrete, rein-
forced concrete or clay)
6.9
Fire-resistant sealant suitable for the fire batt
system used
6.10
Ablative coating around the perimeter, thick-
ness 2.5 mm
6.11
Insulating strip (depending on wall construc-
tion)
6.12
Intumescent seal
6.13
Mineral wool strips A1,
≤
5 mm thick,
≤
1000°C, filler as an alternative
6.14
Armaflex
6.15
Mineral wool (depending on the flexible
ceiling joint)
6.16
Armaflex AF / Armaflex Ultima
6.17
Fire batt (Hensel)
6.18
Nomenclature
Fire damper FKR-EU
155
Содержание FKR-EU
Страница 162: ...Fire damper FKR EU 162 ...
Страница 163: ...Fire damper FKR EU 163 ...
Страница 164: ...Fire damper FKR EU 164 ...