206-3 -- Wireless

Entry/Exit Signal Kit

Instruction Sheet

Trou

bleshooting

PHONE: (203) 730-1756

FAX: (203) 730-1781

2 PARKLAWN DR.  STE F, BETHEL, CT 06801

[email protected]

 www.trineonline.com

NOTE: This unit is NOT compatible with 206-3

units sold before 

December, 2014

For

 swingin

g doors

align

 the tran

smitter

arr

ow t

o the bottom

of the magn

et

as sho

wn.

V. 16.0504

• 

Transmitter 

communicates with the 

chime wirelessly.

• 

Can be used with swinging 

or sliding doors

• 

Chime plugs into a 

standard electric outlet

• 

Includes a Door Magnet 

Spacer and all the 

mounting screws

• 

Transmitter range: 100’

• Three 

High Quality Chime 

tunes

• 

(1) 12V A23 Battery is 

included

A. Pr

oblem

: Chime does not rin

g one time 

and st

op.

1a. P

ossible Cause: Sen

sor ba

tter

y is not 

installed pr

oper

ly.

1b. Fix: Make sur

e batter

y is insta

lled 

accor

ding t

o the diagra

m inside sen

sor.

2a. P

ossible Cause: Sen

sor ba

tter

y is dead.

2b. Fix:  R

eplace sensor b

atter

y.

3a. P

ossible Cause: Chime is n

ot receivin

pow

er

3b. Fix:  Ma

ke sur

e the plug-in c

hime has 

pow

er

4a. P

ossible Cause: Sen

sor & Chime a

re no

synced

4b. Fix:  R

e-try syn

cing pr

ocess

 

- Unplug c

hime

 

- Ensur

e switc

h 1 on

 both c

hime and 

sensor

 is set t

o OFF

 

- Wait 30 Secon

ds

 

- Press and hold the “

TEST” button

 

inside the sen

sor within 20 secon

ds after

 

plugging in chime.  When the “Din

g-dong” 

tune is pla

yed, the sen

sor is syn

ced with 

the chime. 

B. Problem

: Batter

y seems okay bu

t the chime 

does not w

ork af

ter in

stallation.

1a. P

ossible Cause: Chime or

 Tran

smitter is 

mounted on

 meta

l or nea

r me

tal stud

s. 

(meta

l redu

ces ran

ge of unit)

1b. Fix: Use a 1/4”

 to 1/2” w

ooden shim t

o to 

move 

Tra

nsmitt

er a

way fr

om meta

l surfa

ce.  

Move Chime t

o another

 wall outle

t.

2a. P

ossible Cause: Chime or

 Tran

smitter  is 

mounted n

ear con

cret

e. (concr

ete r

educes 

range of u

nit)

2b. Fix:  Mo

ve a

way fr

om concret

e

3a. P

ossible Cause: Chime & T

ransmitt

er ar

installed t

oo far a

part (o

ver

 100 f

eet)

3b. Fix:  reloca

te pieces closer

 to on

e ano

ther.

C. Problem

: Chime sounds when

 not in

ten

ded.

1. P

ossible Cause: Chime or

 Tra

nsmitter is 

receivin

g inter

fer

ence

2. Fix: Follo

w A. Pr

oblem - 4b. Fix to Un

sync the 

unit

 

-  Follo

w A. Pr

oblem - 4b. Fix A

gain to 

Resyn

c the units

 

- If prob

lem persists mo

ve 

Chime or 

Tran

smitter t

o ano

ther loca

tion to red

uce 

inter

fer

ence.

FEATURES:

NOTE: This u

nit is NO

compatible with 206-3

units sold 

before

December

, 2014

What’s Included:

Installation:

Chime

(Plug in)

**Note: Arrows do not line up**

**Position as shown**

Door

Magnet

Door

Magnet

Wireless

Transmitter

Spacer

Mounting

Screws

Chime Selection Chart

Transmitter

& Trigger

Screws

Magnet

Spacer

Magnet

Spacer

1. Plug the chime on an electric outlet within the 

range of the transmitter. It will take 30 seconds for 

the electronics to initialize.

2. Take off the back cover of the transmitter unit to 

find the programming switches.

3. After the chime initializes, push the “Test Button” 

on the transmitter for 20 seconds so the chime can 

pair with the transmitter.

Note: 

A “Ding-Dong” sound from the chime indicates that 

the transmitter has been successfully mated with the 

chime.

A single “Ding” from the chime indicates that the 

transmitter memory was erased.

4. Select the desired chime sound. See the selection 

chart for the dip switch combinations.

5. Mount the transmitter unit on to the door frame.

6. ** Align the door magnet with the transmitter - 

see door positioning above**

 Use the door magnet 

spacer if the door is recessed too far from the frame.

7. Test the completed installation. Refer to the trou-

bleshooting section if the installation does not work.

Transmitter

Chime

Test

Button

Transmitter

Dip Switch

Transmitter

Switch 2 - ON

Switch 2 - OFF
Switch 2 - OFF

Switch 2 - ON

Tune

Ding

Ding-Dong
Ding-Dong

Westminster

Chime

Switch 2 - ON

Switch 2 - OFF
Switch 2 - OFF

Switch 2 - ON

Содержание 4100 Electric Strike

Страница 1: ...rike position if possible 5 Correct excessive warping of door USING THE LATCH SPACER SHIMS CONTINUED For locks not aligning to the vertical center of the strike mount the shims as shown below Most if...

Страница 2: ...nnect socket to the power wires coming out of the frame 5 Connect the strikes bottom terminal to the quick connect socket 6 Tuck the wires inside the door frame 7 Install the electric strike into the...

Страница 3: ...s 50 Ohms 24AC 50 60Hz 420 Amps 10 08 Watts 50 Ohms 4200 ELECTRICAL CHARACTERISTICS OPERATING TEMP RANGE 20 C TO 40 C DO NOT APPLY A VOLTAGE OF MORE THAN 10 OVER THE RATED OPERATING VOLTAGE OF THE STR...

Страница 4: ...ON FACEPLATE DIMENSIONS Metal Frame TAB DIMENSIONS Wood Frame Use 12 24 x 1 2 inch Philips Mounting Screws for tab holes Aluminum Frame MOUNTING TABS 2 SUPPLIED 4 7 8 1 17 64 4 1 8 3 3 8 1 1 16 8 1 16...

Страница 5: ...power ONLY as the last step 3 Carefully choose the quick connect socket to match the required voltage The quick connect sockets are labeled 12VDC Blue Wire or 24VDC White Wire 4 Use the crimp connecto...

Страница 6: ...or 4 Adjust electric strike position if possible 5 Correct excessive warping of door PHONE 718 829 2332 FAX 718 829 6405 1440 FERRIS PLACE BRONX NY 10461 email customerservice trineonline com website...

Страница 7: ...WITCH NORMALLY CLOSED FAIL SAFE CONFIGURED STRIKE USE 12V THRU 24V AC OR DC TRANSFORMER TO 120V AC LINE WIRING FOR FAIL SAFE MODE WITH OPTIONAL BUZZER SWITCH SINGLE POLE DOUBLE THROW FAIL SAFE CONFIGU...

Страница 8: ...WITCH NORMALLY CLOSED FAIL SAFE CONFIGURED STRIKE USE 12V THRU 24V AC OR DC TRANSFORMER TO 120V AC LINE WIRING FOR FAIL SAFE MODE WITH OPTIONAL BUZZER SWITCH SINGLE POLE DOUBLE THROW FAIL SAFE CONFIGU...

Страница 9: ...le the 4850 is unlatched swing the door open If the door opens then the bolt maybe applying pressure to the latch Adjust the position of the 4850 to relieve the pressure POSSIBLE REMEDIES 1 Re adjust...

Страница 10: ...Push the anchor pins in the back of any 4850 series strike if you desire to use this Figure 5 Crimp the quick connect socket assembly to the power wires Crimp Connectors Quick Connect Socket Assembly...

Страница 11: ...tch cavity Having the latch on center will ensure that the sensor will have enough surface to detect You can use the 1 8 and 1 4 spacer included 1 4 is for 4850LB only to move the 4850LB 4800FLB close...

Страница 12: ...RELAY PANEL INDICATOR OR OTHER SIGNALING DEVICE POWER SUPPLY 1 POWER SUPPLY 2 POWER SUPPLY 3 CONTROL PANEL PANEL SIDE WIRING FRAME SIDE WIRING Hook up to either Normally Open or Normally Closed Termin...

Страница 13: ...Solid Cast Latch Stainless Steel Cavity Width 5 8 Height 1 1 8 Depth 1 2 Non handed Heavy duty latch spring Silent Operation Intermittent Duty with the Standard versions Intermittent and Continuous D...

Страница 14: ...ubricating these units will actually hamper their performance by attracting dust and debris into the tight tolerance precision Micro Solenoid assembly GETTING STARTED Before proceeding with your insta...

Страница 15: ...ed to as Silent Operating unlike some types of AC electric releases which make a buzzing sound when activated For some applications such as entrances into apartment buildings or storerooms an audible...

Страница 16: ...16 1 1 32 1 1 4 3 1 8 1 1 8 1 5 16 9 16 3 32 5 16 1 OPTIONAL 1 16 THICK SHIM Page 4 4 7 8 1 1 4 1 7 8 1 1 32 1 11 16 1 3 32 4 1 8 3 4 3 11 32 5 8 3 8 OPTIONAL 1 16 THICK SHIM 1 1 4 4 7 8 3 32 1 1 16...

Страница 17: ...he 3234 s 2 3 4 x 1 1 4 faceplate requires the least amount of jamb preparation when compared with other electric strikes WIRING DIAGRAM 24V DC OR 12V DC TRANSFORMER OPTIONAL BUZZER BZ 12 or BZ 24 TO...

Страница 18: ...serviceable part Note that intermittent coils can only receive power for 1 minute or less 3 If voltage IS NOT present Verify Circuit breaker is on Verify voltage at the transformer power supply output...

Страница 19: ...power to the receptacle into which you will plug your transformer power supply This will enable you to safely cut power during installation and permit troubleshooting if required 5 Verify that the rec...

Страница 20: ...must remain UNLOCKED for extended periods or when required by code The TRINE LC version of MODEL 3258 3458 3258RS and 3458RS can be used for INTERMITTENT DUTY AND CONTINUOUS DUTY ELECTRICAL If you ar...

Страница 21: ...a buzzing sound is distracting or disturbing Verify with your client which they require and if an audible signal when the electric release is activated is desirable then add a audible visual annunciat...

Страница 22: ...AC TRANSFORMER PUSH BUTTON NORMALLY OPEN The rectifier can be positioned before of after the push button in the circuit The LC module can ONLY be positioned after the push button as shown above The L...

Страница 23: ...8 2 7 16 5 8 13 16 2 1 8 1 11 16 1 1 32 1 11 16 1 1 8 ALUMINUM FRAME INSTALLATION The 3458 s 4 5 8 x 1 9 16 full lip steel faceplate requires the least amount of jamb preparation when compared with ot...

Страница 24: ...maged wiring or bad wire splices SYMPTOM Door will not open but strike is working Check for other locks on door Check for proper lock latch engagement SEE SECTION CONFIRMING PROPER LOCK LATCH ENGAGEME...

Страница 25: ......

Страница 26: ...s 2 12 24 x 1 2 EN MTS 14 Shim Kit 3 1 16 Shim EN UNV SHIM 15 Shim Screws 2 6 32 x 1 4 EN SHIM SCR S 16 Shim Screws 2 6 32 x 3 8 EN SHIM SCR L Figure 1 EN400 Electric Strike NOTE Number in parenthesis...

Страница 27: ...all the pivot holes lines up Assemble the Solenoid and secure it with the solenoid Screw as shown Finish the assembly by installing the Cover and securing it with the two assembly Screws Assemble the...

Страница 28: ...the or BLACK negative side wire terminal to the negative side of the circuit RED BLACK INSTALLATION PROCEDURE For new or replacement installation in wood or metal jambs 1 Verify that voltage rating of...

Страница 29: ...releases and that there is sufficient Spring tension to push it to closed positionwhen released If Latch does not have Spring tension disassemble Electric Strike and inspect for improperly installed...

Страница 30: ...icates part in Parts List UL LISTED 10B fire rated class A 3 hour Single Swing Doors UL LISTED 1034 Burglary Resistant Locking Mechanism for Indoor or Outdoor Use ANSI BHMA A156 5 1992 4 7 8 X 1 1 4 F...

Страница 31: ...e to fail safe when replaced with special order part EN SLR RS When using the fail safe Slider a DC Coil must be used The fail safe Slider is identified by the small dimple below the welded tip CHANGI...

Страница 32: ...be employed ELECTRICAL CHARACTERISTICS CHART FAIL SECURE Intermittent Duty NORMALLY LOCKED VOLTAGE CURRENT AMPS OHMS SOUND DUTY 12 VAC 70 4 5 Buzz Intm 24 VAC 37 18 0 Buzz Intm 12 VDC 28 43 0 Silent...

Страница 33: ...ric Strike or Coil Assembly Use voltmeter to verify that Electric Strike is receiving proper voltage and that wiring is not shorted If voltage is too low because wire size is too small for length or w...

Страница 34: ...Figure 1 EN800 Electric Strike NOT PART OF ASSEMBLY USED ONLY DURING DISASSEMBLY OR CHANGING FAIL SECURE ACTION UNLESS OTHERWISE SPECIFIED FRAME IS SUPPLIED AS SATIN STAINLESS STEEL US32D SPECIFY OTHE...

Страница 35: ...The EN Electric Strike must be installed with coil assembly up wiring toward top of unit In this position the Electric Strike will be locked without power Fail Secure or locked with power Fail Safe ac...

Страница 36: ...AGE CURRENT AMPS OHMS SOUND DUTY 12VAC 70 4 5 Buzz Intermittent 24VAC 37 18 0 Buzz Intermittent 12VDC 28 43 0 Silent Inter Cont 24VDC 15 164 0 Silent Inter Cont 4 If required run new wiring to door fr...

Страница 37: ...ric Strike or Coil Assembly Use voltmeter to verify that Electric Strike is receiving proper voltage and that wiring is not shorted If voltage is too low because wire size is too small for length or w...

Страница 38: ...7 Frame EN 9 FR 8 Assembly Pin EN ASS PN 9 Spring EN SPR 10 Latch Pivot Shaft EN LCH PV ST 11 Guard EN GRD 12 Plastic Cap EN PLC 13 Support Plate EN 9 SP 14 Mounting Screws 2 12 24 1 2 EN MTS 15 Shim...

Страница 39: ...E The EN Electric Strike must be installed with coil assembly up wiring toward top of unit In this position the Electric Strike will be locked without power Fail Secure or locked with power Fail Safe...

Страница 40: ...AGE CURRENT AMPS OHMS SOUND DUTY 12VAC 70 4 5 Buzz Intermittent 24VAC 37 18 0 Buzz Intermittent 12VDC 28 43 0 Silent Inter Cont 24VDC 15 164 0 Silent Inter Cont 4 If required run new wiring to door fr...

Страница 41: ...ric Strike or Coil Assembly Use voltmeter to verify that Electric Strike is receiving proper voltage and that wiring is not shorted If voltage is too low because wire size is too small for length or w...

Страница 42: ...t go into slots Fail Safe Indication Back Case 2 Insert assembly pin provided to remove latch pin latch Note The slider should fall thru the strike body after latch is removed remove slider slider gua...

Страница 43: ...r as shown Replace back cover Replace 2 screws and tighten 9 Replacing coil assembly Note Slider must be in position between brackets of coil assembly Note Position wires thru slot toward front of the...

Страница 44: ...n provided to remove latch pin latch Note The slider should fall thru the strike body after latch is removed remove slider slider guard 3 To change the action remove the slider from the frame and reve...

Страница 45: ...e sure slider is free to move up down with no resistance 12 Thread wires thru cover as shown Replace back cover Replace two 1 8 screws and tighten 10 Replacing coil assembly Note Slider must be in pos...

Страница 46: ...k up to either Normally Open or Normally Closed Terminal EN400 EN800 EN850 EN950 EN960 LBSM WIRING SCHEMATIC SWITCHED POWER CONSTANT POWER FIVE WIRE SCHEMATIC UTILIZING ONE TRANSFORMER This wiring arr...

Страница 47: ...DULE CONSTANT POWER 1440 Ferris Place Bronx New York 10461 SIX WIRE SCHEMATIC UTILIZING TWO TRANSFORMERS This wiring arrangement is used to isolate the strike operation from the LB and or the SLIDER s...

Страница 48: ...about approved installation procedures Contact rating 10 Amps at 120 volts 5 Amps at 250 volts DO NOT EXCEED CONTACT RATING CONTENTS 1 UL CSA listed switch 1 Faceplate 2 Wire leads UL Listed w Connect...

Страница 49: ...if used Insulate all connections with wire nuts or tape approved by local codes The door switch can be mounted to the switch case with the 2 flat head screws supplied In the event that the light stays...

Страница 50: ...ing 5 Battery compartment BATTERY INSTALLATION This unit operates on 3VDC batteries using 2 pieces UM 2 size C 1 5V R14 batteries or equivalent Press and slide out the battery door insert batteries in...

Страница 51: ...t 2b Fix Move away from concrete 3a Possible Cause Chime Transmitter are installed too far apart over 100 feet 3b Fix relocate pieces closer to one another C Problem Chime sounds when not intended 1 P...

Страница 52: ...t 2b Fix Move away from concrete 3a Possible Cause Chime Transmitter are installed too far apart over 100 feet 3b Fix relocate pieces closer to one another C Problem Chime sounds when not intended 1 P...

Страница 53: ...ompartment polarity may damagethe unit FEATURES 1 Easy installation 2 Audible alarm for doors windows 3 105dB instant alarm 4 LR44 battery 3 pcs Check that the batteries are installed with correct pol...

Страница 54: ...n the battery becomes weak then it s time to replace the batteries If the unit functions abnormally first check the battery and replace as required The unit is composed of two parts the audible transm...

Страница 55: ...61 3699 PH 718 829 2332 FAX 718 829 6405 E mail customerservice trineonline com www trineonline com 230 8 Note 231 2 Note Push Button Instructions Expand Your Wireless Chime System The 2 note 231 8 no...

Страница 56: ...sh button and chime codes are the same Check orientation of push button battery Check charge of push button and chime batteries replace if necessary Batteries seem OK but the chime doesn t work when i...

Страница 57: ...might require the use of tweezers to remove and replace the jumpers ONE YEAR LIMITED WARRANTY TRINE ACCESS TECHNOLOGY reserves the right to discontin ue and to change specifications at any time witho...

Страница 58: ...s Dong one note and Ding Dong two note The factory setting is for the Ding Dong tune This tune can be changed by following the instructions below Dong one note tune Push button Add jumper to location...

Страница 59: ...s to mount base to wall 5 Connect wires to terminal screws marked Front Transformer and Rear on the chime base 6 Place chime cover securely over the base NOTE FOR LOUDER SOUNDING CHIME PERFORMANCE A 2...

Страница 60: ...w radiant receiver SPECIFICATIONS 1 BOTH PUSH BUTTONS ON THE 018 2 WILL TRIGGER THE 017TDC 2 The 017TDC 2 3 will work with a range of operating voltages These voltages are from 12 Volts through 30 Vol...

Страница 61: ...ITCHES FIGURE 4 TRANSFORMER For DC ONLY For DC ONLY For DC ONLY For DC ONLY Power Supply 12 30 V AC DC Fail Secure Strike 1 Fail Secure Strike 2 USE THE COPPER SHUNT INCLUDED TO SUPPLY POWER TO THE ST...

Страница 62: ...e receiver and the 018 2 transmitter SECURITY CODE SWITCHES FIGURE 8 EXAMPLE CODE SETTING MUST BE THE SAME SWITCH COMBINATION FIGURE 9 FIGURE 10 TIME DELAY KNOBS 017TDC 2 017TDC 3 3 Optionally you can...

Страница 63: ...ections may be faulty Security Code mismatch Wiring connection may be faulty RF interference Security Code mismatch Faulty power supply Loose wiring connections or shorted wire Replace the battery Use...

Страница 64: ...sen the transmitter s assembly screw and snap the front cover open Match the coding of the receiver Figure 1 below shows the location of the DIP switches for the 017TDC 2 3 receiver and the 018 2 tran...

Страница 65: ...hances of installation success Before screwing the 017TDC receiver down choose an initial location and use a 10 feet electrical cord and walk test the 017TDC s sensitivity to receive the 018 2 s signa...

Отзывы: