SIX WIRE SCHEMATIC UTILIZING TWO TRANSFORMERS
This wiring arrangement is used to isolate the strike operation, from the LB and/or the SLIDER sensor and
power board and the Panel Indicator or Signaling Device.
WHITE - NORMALLY CLOSED (NC)
BLACK -
RED +
BLUE COMMON (COM)
YELLOW - NORMALLY OPEN (NO)
GRAY - NORMALLY CLOSED (NC)
GREEN COMMON (COM)
ORANGE - NORMALLY OPEN (NO)
POWER TO STRIKE
POWER TO STRIKE
120
VAC
12 - 24 VDC
OUTPUT
12 - 24 VDC
OUTPUT
CONTROL SWITCH
OR RELAY
PANEL INDICATOR
OR OTHER
SIGNALING DEVICE
POWER
SUPPLY 1
120
VAC
POWER
SUPPLY 1
PANEL SIDE
WIRING
FRAME SIDE
WIRING
CONTROL
PANEL
Hook-up to either Normally Open
or Normally Closed Terminal
Hook-up to either Normally Open
or Normally Closed Terminal
EN400, EN800, EN850, EN950, EN960 LBSM WIRING SCHEMATIC
SWITCHED POWER
CONSTANT POWER
FIVE WIRE SCHEMATIC UTILIZING ONE TRANSFORMER
This wiring arrangement uses the least amount of conductors between the Panel and the Frame.
FRAME SIDE
WIRING
120
VAC
12VDC
OUTPUT
CONTROL SWITCH
OR RELAY
PANEL INDICATOR
OR OTHER
SIGNALING DEVICE
POWER
TRANS-
FORMER
CONTROL
PANEL
PANEL SIDE
WIRING
Hook-up to either Normally Open
or Normally Closed Terminal
Hook-up to either Normally Open
or Normally Closed Terminal
WHITE - NORMALLY CLOSED (NC)
BLACK -
RED +
BLUE COMMON (COM)
YELLOW - NORMALLY OPEN (NO)
GRAY - NORMALLY CLOSED (NC)
GREEN COMMON (COM)
ORANGE - NORMALLY OPEN (NO)
POWER TO STRIKE
POWER TO STRIKE
SWITCHED POWER
CONSTANT
POWER
WIRING SCHEMATICS FOR DIFFERENT APPLICATIONS
1440 Ferris Place
Bronx
New York
10461
Содержание 4100 Electric Strike
Страница 25: ......