Chapter 5 Function parameter
40
No. Code
Parameter name
Setting range
Factory
default
Change
190. E3.00 VDI1 function selection 0 to 25
0
★
191. E3.01 VDI2 function selection 0 to 25
0
★
192. E3.02 VDI3 function selection 0 to 25
0
★
193. E3.03 VDI4 function selection 0 to 25
0
★
194. E3.04 VDI5 function selection 0 to 25
0
★
195. E3.05 VDI active mode
Units digit: Virtual VDI1
Tens digit: Virtual VDI2
Hundreds digit: Virtual VDI3
Thousands digit: Virtual VDI4
Ten thousands digit: Virtual
VDI5
00000
☆
196. E3.06 VDI status setting
Units digit: Virtual VDI1
Tens digit: Virtual VDI2
Hundreds digit: Virtual VDI3
Thousands digit: Virtual VDI4
Ten thousands digit: Virtual
VDI5
11111
★
197. E3.07 AI1_DI
function
0 to 25
0
★
198. E3.08 AI2_DI function
selection
0 to 25
0
★
199. E3.09 Panel potentiometer_DI
setting
0 to 25
0
★
200. E3.10 AI_DI
mode
Units digit: AI1
0: high level active
1: low level active
Tens digit: AI2 (same as units
digit)
Hundreds digit: Panel
potentiometer (same as units
digit)
000
★
201. E3.11 VDO1 output function 0 to 10
0
☆
202. E3.12 VDO2 output function 0 to 10
0
☆
203. E3.13 VDO3 output function 0 to 10
0
☆
204. E3.14 VDO4 output function 0 to 10
0
☆
205. E3.15 VDO5 output function 0 to 10
0
☆
Chapter 5 Function parameter
41
206. E3.16 VDO valid state
Units digit: VDO1
0: positive logic
1: negative logic
Tens digit: VDO2 (same as
units digit)
Hundreds digit: VDO3 (same as
units digit)
Thousands digit: VDO4 (same
as units digit)
Ten thousands digit: VDO5
(same as units digit)
00000
☆
207. E3.17 VDO1 delay time
0.0 to 3600.0s
0.0 s
☆
208. E3.18 VDO2 delay time
0.0 to 3600.0s
0.0 s
☆
209. E3.19 VDO3 delay time
0.0 to 3600.0s
0.0 s
☆
210. E3.20 VDO4 delay time
0.0 to 3600.0s
0.0 s
☆
211. E3.21 VDO5 delay time
0.0 to 3600.0s
0.0 s
☆
5-1-18.b0 Group - Motor parameters
No. Code
Parameter name
Setting range
Factory
default
Change
212. b0.00 Inverter type
0: G-type machine; 1: Reserved
0
★
213. b0.01 Rated motor power
0.4 to 900.0kW
Depends on
models
★
214. b0.02 Rated motor voltage
0 to 460V
Depends on
models
★
215. b0.03 Rated motor current
0.1 to 2000.0A
Depends on
models
★
216. b0.04 Rated motor frequency
0.01Hz to F0.08 (maximum
output frequency)
50.00Hz
★
217. b0.05 Rated motor speed
0 to 36000rpm
Depends on
models
★
218. b0.06 Motor stator resistance 0.001 to 65.535
Ω
Depends on
models
★
219. b0.07 Motor rotor resistance 0.001 to 65.535
Ω
Depends on
models
★
220. b0.08
Motor stator and rotor
inductance
0.1 to 6553.5mH
Depends on
models
★
221. b0.09
Motor stator and rotor
mutual inductance
0.1 to 6553.5mH
Depends on
models
★
Содержание CA-203A
Страница 1: ...Vector control inverter Operating manual CA Series www tpg tw com...
Страница 61: ...1 TPG Corp TPG Corp 1 1 1 1 1 1 1 1 1 2 1 2...
Страница 62: ...2 1 2 U V W EMC P RB R S T U V W 3 U V W AC36V 1 3 1 500V 5M 2 3 0Hz 400Hz 50Hz 4 5 PWM...
Страница 63: ...4 6 PWM 7 8 CA 9 CA 10 11 1000m 12 13 14 1 2 3 4 5 15 1 U V W 2 3 4 5 5 6 MOS IGBT 7 E 8 CE 1 4...
Страница 70: ...18 4 7 CA Series K1 K1 K1 R S T MC1 MC2 MC1 MC2 M 3 4 5 19 4 8 4 6 R S T...
Страница 101: ...80 7 1 3 7 3 81 8 1 6 LED OLED 2 1 R S T U V W IGBT 8 2...
Страница 109: ...MODBUS 05H 06H 07H 08H EPPROM...