Chapter 5 Function parameter
42
222. b0.10 Motor no-load current 0.01 to 655.35A
Depends on
models
★
223. b0.11
Motor parameter auto
tunning
0: no operation
1: Motor parameters static
auto tunning
2: Motor parameters
comprehensive auto tunning
0
★
5-1-19.y0 Group - Function code management
No. Code
Parameter name
Setting range
Factory
default
Change
224. y0.00
Function parameter
recovery
0: no operation
1: Restore factory settings,excluding
motor parameters
2: Clear fault history
3: Restore factory settings,including
motor parameters
4: Backup parameters
5: Restore from backup
0
★
225. y0.01 User password
0 to 65535
0
★
5-1-20.y1 Group - Fault history search
No. Code
Parameter name
Setting range
Factory
default
Change
226. y1.00 Type of the first two faults
0 to 22
0
●
227. y1.01 Type of the first fault
0 to 22
0
●
228. y1.02 Type of current fault
0 to 22
0
●
229. y1.03 Running frequency of current fault
0.00Hz
●
230. y1.04 Output current of current fault
0.0A
●
231. y1.05 Bus voltage of current fault
0V
●
232. y1.06 Input terminal status of current fault
0
●
233. y1.07 Output terminal status of current fault
0
●
5-2.Function parameter description
5-2-1.dO Group - Monitoring function group
d0 parameters group is used to monitor the inverter running status information,user
can view those information through the panel to facilitate on-site commissioning, also
read parameters group value via communication for host computer monitoring.
Chapter 5 Function parameter
43
Parameter
function code
Parameter name
Smallest unit
d0.00
Running frequency
0.01Hz
Actual output frequency of inverter running.
d0.01
Set frequency
0.01Hz
Inverter current actual setting frequency
d0.02
DC bus voltage
1V
Inverter bus voltage value
d0.03
Inverter output voltage
1V
Actual output voltage when the inverter running
d0.04
Inverter output current
0.1A
Actual output current when the inverter running
d0.05
Inverter output power
0.1kW
Actual output power when the inverter running
d0.06
Inverter output torque
1%
Actual output torque percentage when the inverter running
d0.07
Input terminal status
-
DI input terminal status is currently displayed, when it is converted into binary
data, one bit corresponds to one DI terminal input signal, 1 indicates that the input
terminal is high level signal, 0 indicates that the input terminal is low-level signal.
Bit0
Bit1
Bit2
Bit3
Bit4
DI1
DI2
DI3
DI4
DI5
Bit5
Bit6
Bit7
Bit8
Bit9
Reserved
Reserved
Reserved
Reserved
Reserved
d0.08
Output terminal status
-
Displays current output terminal state value. When it is converted into binary data,
one bit corresponds to one output terminal input signal, 1 indicates that the input
terminal is high level signal, 0 indicates that the output terminal is low-level signal.
Bit0
Bit1
Bit2
Bit3
Bit4
MO1
Reserved
Reserved
R0
Reserved
d0.09
Analog AI1 value
0.01V
Analog AI1 input voltage value
d0.10
Analog AI2 value
0.01V
Содержание CA-203A
Страница 1: ...Vector control inverter Operating manual CA Series www tpg tw com...
Страница 61: ...1 TPG Corp TPG Corp 1 1 1 1 1 1 1 1 1 2 1 2...
Страница 62: ...2 1 2 U V W EMC P RB R S T U V W 3 U V W AC36V 1 3 1 500V 5M 2 3 0Hz 400Hz 50Hz 4 5 PWM...
Страница 63: ...4 6 PWM 7 8 CA 9 CA 10 11 1000m 12 13 14 1 2 3 4 5 15 1 U V W 2 3 4 5 5 6 MOS IGBT 7 E 8 CE 1 4...
Страница 70: ...18 4 7 CA Series K1 K1 K1 R S T MC1 MC2 MC1 MC2 M 3 4 5 19 4 8 4 6 R S T...
Страница 101: ...80 7 1 3 7 3 81 8 1 6 LED OLED 2 1 R S T U V W IGBT 8 2...
Страница 109: ...MODBUS 05H 06H 07H 08H EPPROM...