![TPG CA-203A Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/tpg/ca-203a/ca-203a_operating-manual_1146153007.webp)
8
Chapter 2 Standard specifications
2-1.Technical specifications
Inverter model
Rated output
Power KW)
Rated input
Current(A)
Rated output
current (A)
Adaptive motor
Power (KW)
Single phase 220V ±10%
CA-203A 0.4 5.4 2.5
0.4
CA-204A 0.75 8.2 4.0
0.75
CA-207A 1.5 14.0 7.0
1.5
CA-210A 2.2 23 10
2.2
Three-phase 220V ±10%
CA-203S 0.4 4.1 2.5
0.4
CA-204S 0.75 5.3 4.0
0.75
CA-207S 1.5 8.0 7.0
1.5
Three-phase 380V ±10%
CA-401S 0.4 2.0 1.2
0.4
CA-403S 0.75 4.3 2.5
0.75
CA-404S 1.5 5.0 3.8
1.5
CA-405S 2.2 5.8 5.1
2.2
CA-409S 3.7 10 8.5
3.7
Note: the 220V voltage level can be used as a brake unit selection; 380V voltage
brake unit as the standard, can not do for selection.
Chapter 2 Standard specifications
9
2-2.Technical specifications
Items
Specifications
Voltage and frequency
levels
Single phase 220V, 50/60Hz
Three-phase 220V, 50/60Hz
Three-phase 380V,50/60Hz
Powe
r
Allowable fluctuation
Voltage: ± 10% ;Frequency: ± 5%
The voltage unbalance rate is less than 3% and the
distortion rate meets the IEC61800-2 standard.
Control system
High performance vector control inverter based on
DSP
Output frequency
0.00 to 400.0Hz
Control method
V/F control
Open-loop flux vector control
Automatic torque
boost function
Realize low frequency (1Hz) and large output
torque control under the V/F control mode.
Frequency setting
resolution
Digital: 0.01Hz
Analog: highest frequency × 0.2%
V/F curve mode
Linear,square root/m-th power,custom V/F curve
Over load capability
Rated Current 150% - 60 seconds, Rated Current
200% - 1 seconds
Slip compensation
Slip compensation available
Carrier Frequency
1kHz to 15kHz
Start torque
0.5Hz/150% (Open-loop flux vector control)
Speed range
1:100 (Open-loop flux vector control)
Steady-speed precision
(Speed control accuracy)
Open-loop flux vector control:
≤
± 0.5% (rated
synchronous speed)
Torque response
≤
40ms (Open-loop flux vector control)
Torque boost
Automatic torque boost; manual torque boost (0.1%
to 30.0%)
Linear ac/deceleration
Linear acceleration and deceleration mode; two
kinds of acceleration and deceleration time; time
range 0.1s to 3600.0s.
DC braking
DC braking frequency: 0.00Hz to max.output
frequency;
Braking time: 0.0 to 50.0 seconds
Braking current value: 0.0% to 150.0%
Jogging control
Jog Frequency Range: 0.00Hz to max.output
frequency;
Jog Ac/deceleration time: 0.1s to 3600.0s
Multi-speed operation
Achieve up to 16-speed operation through the
control terminal
Control system
Built-in PID
Easy to realize closed-loop control system for the
process control.
Содержание CA-203A
Страница 1: ...Vector control inverter Operating manual CA Series www tpg tw com...
Страница 61: ...1 TPG Corp TPG Corp 1 1 1 1 1 1 1 1 1 2 1 2...
Страница 62: ...2 1 2 U V W EMC P RB R S T U V W 3 U V W AC36V 1 3 1 500V 5M 2 3 0Hz 400Hz 50Hz 4 5 PWM...
Страница 63: ...4 6 PWM 7 8 CA 9 CA 10 11 1000m 12 13 14 1 2 3 4 5 15 1 U V W 2 3 4 5 5 6 MOS IGBT 7 E 8 CE 1 4...
Страница 70: ...18 4 7 CA Series K1 K1 K1 R S T MC1 MC2 MC1 MC2 M 3 4 5 19 4 8 4 6 R S T...
Страница 101: ...80 7 1 3 7 3 81 8 1 6 LED OLED 2 1 R S T U V W IGBT 8 2...
Страница 109: ...MODBUS 05H 06H 07H 08H EPPROM...