Chapter 5 Function parameter
84
b0.08
Motor stator and rotor
inductance
0.1 to 6553.5mH
Depends on
models
★
b0.09
Motor stator and rotor
mutual inductance
0.1 to 6553.5mH
Depends on
models
★
b0.10 Motor no-load current
0.01 to 655.35A
Depends on
models
★
When the motor parameter auto tunning is competed, the set value of b0.06 to
b0.10 will be automatically updated. These parameters as the basis of high-
performance vector control have a direct impact on the control performance.
Note: user should not arbitrarily change the group of parameters.
b0.11 Motor parameter auto
tunning
0: no operation
1: Motor parameters static auto
tunning
2: Motor parameters
comprehensive auto tunning
0
☆
0: no operation
1: Static parameter auto tunning: you do not need to disengage the motor and its
load, must enter the correct motor nameplate parameters (b0.01 to b0.05) before motor
parameter auto tunning, the resistance value of motor stator will be detected after motor
parameter auto tunning. The mutual inductance and the no-load current of motor will
not be measured, user can enter the appropriate values based on experience.
2: Rotation parameter auto tunning: you must enter the correct motor nameplate
parameters (b0.01 ~ b0.05) before motor parameter auto tunning, and disengage the
motor and its load so that the motor is in the state of rest or no-load, otherwise the
result of motor parameter auto tunning may be incorrect.
Before motor parameter auto tunning, set appropriate acceleration time and
deceleration time (F0.05, F0.06) based on the size of the motor inertia, otherwise it
may occur overcurrent or overvoltage fault in the process of motor parameter auto
tunning.
Set b0.11 to 2 and then press ENTER key to start the state of motor parameter auto
tunning, at this time, the LED displays "-TUN-" and flashes, press RUN key to start
parameter auto tunning, when "TUN-0 ~ TUN-3 " is displayed, TUN-4 motor starts
running. When the parameter auto tunning is completed, display "-END-", and finally
return to the stop interface. When "-TUN-" is flashing, press PRG to exit the state of
parameter auto tunning.
When performing parameter auto tunning, press STOP/RESET key to terminate
the operation of parameter auto tunning.
Note: The start and stop of parameter auto tunning can be only controlled by the
keyboard; when parameter auto tunning is completed, this function code automatically
returns to 0.
5-2-19.y0 Group - Function code management
Code
Parameter name
Setting range
Factory
default
Change
Chapter 5 Function parameter
85
y0.00
Function parameter
recovery
0: no operation
1: Restore factory settings, without
motor parameters
2: Clear fault history
3: Restore factory settings,including
motor parameters
4: Backup parameters
5: Restore from backup
0
★
0: no operation
1: Restore factory settings, without motor parameters
2: Clear fault history
3: Restore factory settings,including motor parameters
4: Backup the parameters set by the current user. Backup all function parameters.
It is easy to restore the default settings when user incorrectly adjust parameters.
5: Restore user backup parameters
Note: This operation is completed, the function code value is automatically
restored to 0; b0 group of parameters will not be restored to the default values and from
Fb.00 to Fb.02 group of parameters.
y0.01
User password
0 to 65535
0
★
When setting to one any non-zero number,the password protection will take effect.
00000: clear old user password, and disable password protection function,
restoring the factory defaultare also able to clear password.
When user password is set and takes effect, if user password is incorrect, user will
not be able to enter parameter menu, only when the correct password is entered, user
can view and modify parameters. Keep firmly in mind the set user password.
Password protection will take effect 1 minute after exiting from function code edit
mode, otherwise inaccessible.
PRG
at this time, if you want to enter function code edit
mode by pressing keys, "0.0.0.0.0" will display, the operator must enter the correct
password.
5-2-20.y1 Group - Fault history search group
Code
Parameter name
Setting range
Factory
default
Change
y1.00 Type of the first two faults
0
●
y1.01 Type of the first fault
0
●
y1.02 Type of current fault
0: No fault
1: Output phase loss (E.oUt1)
2: retain
3: Manufacturers set time to
arrive (E.oUt3)
4: Acceleration overcurrent
(E.oC1)
5: Deceleration overcurrent
(E.oC2)
6: Constant speed overcurrent
(E.oC3)
7: Acceleration overvoltage
(E.oU1)
8: Deceleration overvoltage
(E.oU2)
0
●
Содержание CA-203A
Страница 1: ...Vector control inverter Operating manual CA Series www tpg tw com...
Страница 61: ...1 TPG Corp TPG Corp 1 1 1 1 1 1 1 1 1 2 1 2...
Страница 62: ...2 1 2 U V W EMC P RB R S T U V W 3 U V W AC36V 1 3 1 500V 5M 2 3 0Hz 400Hz 50Hz 4 5 PWM...
Страница 63: ...4 6 PWM 7 8 CA 9 CA 10 11 1000m 12 13 14 1 2 3 4 5 15 1 U V W 2 3 4 5 5 6 MOS IGBT 7 E 8 CE 1 4...
Страница 70: ...18 4 7 CA Series K1 K1 K1 R S T MC1 MC2 MC1 MC2 M 3 4 5 19 4 8 4 6 R S T...
Страница 101: ...80 7 1 3 7 3 81 8 1 6 LED OLED 2 1 R S T U V W IGBT 8 2...
Страница 109: ...MODBUS 05H 06H 07H 08H EPPROM...