![TPG CA-203A Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/tpg/ca-203a/ca-203a_operating-manual_1146153022.webp)
Chapter 5 Function parameter
38
5-1-14.E0 Group - Wobbulate control
No. Code
Parameter name
Setting range
Factory
default
Change
158. E0.00 Wobbulate range
0.0 to 100.0% (relative to
setting frequency)
0.0%
☆
159. E0.01
Sudden jump
frequency range
0.0 to 50.0% (relative to
Wobbulate amplitude)
0.0%
☆
160. E0.02 Wobbulate rise time 0.1 to 3600.0s
5.0 s
☆
161. E0.03 Wobbulate fall time 0.1 to 3600.0s
5.0 s
☆
5-1-15.E1 Group - Multi-speed control
No. Code
Parameter name
Setting range
Factory
default
Change
162. E1.00 Multi-speed 0
-100.0 to 100.0%
0.0%
☆
163. E1.01 Multi-speed 1
-100.0 to 100.0%
0.0%
☆
164. E1.02 Multi-speed 2
-100.0 to 100.0%
0.0%
☆
165. E1.03 Multi-speed 3
-100.0 to 100.0%
0.0%
☆
166. E1.04 Multi-speed 4
-100.0 to 100.0%
0.0%
☆
167. E1.05 Multi-speed 5
-100.0 to 100.0%
0.0%
☆
168. E1.06 Multi-speed 6
-100.0 to 100.0%
0.0%
☆
169. E1.07 Multi-speed 7
-100.0 to 100.0%
0.0%
☆
170. E1.08 Multi-speed 8
-100.0 to 100.0%
0.0%
☆
171. E1.09 Multi-speed 9
-100.0 to 100.0%
0.0%
☆
172. E1.10 Multi-speed 10
-100.0 to 100.0%
0.0%
☆
173. E1.11 Multi-speed 11
-100.0 to 100.0%
0.0%
☆
174. E1.12 Multi-speed 12
-100.0 to 100.0%
0.0%
☆
175. E1.13 Multi-speed 13
-100.0 to 100.0%
0.0%
☆
176. E1.14 Multi-speed 14
-100.0 to 100.0%
0.0%
☆
177. E1.15 Multi-speed 15
-100.0 to 100.0%
0.0%
☆
178. E1.16 Section 0 given mode 0 to 5
0
☆
5-1-16.E2 Group - PID control
Chapter 5 Function parameter
39
No. Code
Parameter name
Setting range
Factory
default
Change
179. E2.00
PID setting source
selection
0: Keyboard setting (E2.01)
1: Analog channel AI1 setting
2: Analog channel AI2 setting
3: Panel potentiometer setting
4: Remote communications
setting
5: Multi-speed setting
0
☆
180. E2.01
Keyboard preset PID
setting
0.0 to 100.0%
50.0%
☆
181. E2.02
PID feedback source
selection
0: Analog channel AI1
feedback
1: Analog channel AI2
feedback
2: Panel potentiometer
feedback
3: AI1-AI2 feedback
4: Remote communications
feedback
5: AI1+AI2 feedback
6: MAX (
︱
AI1
︱
,
︱
AI2
︱
)
7: MIN (
︱
AI1
︱
,
︱
AI2
︱
)
0
☆
182. E2.03 PID output selection
0: PID output is positive
1: PID output is negative
0
☆
183. E2.04
Proportional gain
(KP)
0.00 to 100.00
1.00
☆
184. E2.05 Integration time (Ti) 0.01 to 10.00s
0.10s
☆
185. E2.06 Differential time (Td) 0.00 to 10.00s
0.00 s
☆
186. E2.07 Sampling period (T) 0.01 to 100.00s
0.10s
☆
187. E2.08
PID control deviation
limit
0.0 to 100.0%
0.0%
☆
188. E2.09
Feedback
disconnection
detection value
0.0 to 100.0%
0.0%
☆
189. E2.10
Feedback
disconnection
detection time
0.0 to 3600.0s
1.0 s
☆
5-1-17.E3 Group - Virtual DI, Virtual DO
Содержание CA-203A
Страница 1: ...Vector control inverter Operating manual CA Series www tpg tw com...
Страница 61: ...1 TPG Corp TPG Corp 1 1 1 1 1 1 1 1 1 2 1 2...
Страница 62: ...2 1 2 U V W EMC P RB R S T U V W 3 U V W AC36V 1 3 1 500V 5M 2 3 0Hz 400Hz 50Hz 4 5 PWM...
Страница 63: ...4 6 PWM 7 8 CA 9 CA 10 11 1000m 12 13 14 1 2 3 4 5 15 1 U V W 2 3 4 5 5 6 MOS IGBT 7 E 8 CE 1 4...
Страница 70: ...18 4 7 CA Series K1 K1 K1 R S T MC1 MC2 MC1 MC2 M 3 4 5 19 4 8 4 6 R S T...
Страница 101: ...80 7 1 3 7 3 81 8 1 6 LED OLED 2 1 R S T U V W IGBT 8 2...
Страница 109: ...MODBUS 05H 06H 07H 08H EPPROM...