Chapter 5 Function parameter
30
9 to 10: Reserved
61.
F2.05 AO1 output lower limit 0.0% to F2.07
0.0%
☆
62.
F2.06
Lower limit
corresponds to AO1
output
0.00V to 10.00V
0.00V
☆
63.
F2.07 AO1 output upper limit F2.05 to 100.0%
100.0%
☆
64.
F2.08
Upper limit corresponds
to AO1 output
0.00V to 10.00V
10.00V
☆
65.
F2.09
MO1 Turn-on delay
time
0.0~3600s
0.0s
☆
66.
F2.10
MO1 Turn-off delay
time
0.0~3600s
0.0 s
☆
67.
F2.11
Turn-on delay time of
relay
0.0~3600s
0.0 s
☆
68.
F2.12
Turn-off delay time of
relay
0.0~3600s
0.0 s
☆
69.
F2.13
Reserved
70.
F2.14
D0 terminal active
status selection
0x00 to 0x1F
00
☆
71.
F2.15
MO1 output type
selection
0: pulse output
1: digital output
☆
72.
F2.16
MO1 pulse output
selection
0:running frequency
1: set frequency
2: output current
3: output torque
4: output power
5: output voltage
6: AI1 input value
7: AI2 input value
8:running speed/RPM
9
~
10: reserved
☆
73.
F2.17
MO1 lower limit of
output pulse
0.0%
~
F2.19
0.0%
☆
74.
F2.18
Lower limit
corresponding M01
pulse output
0.1-10kHz
0.0kHz
☆
75.
F2.19
Higher limit of M01
pulse output
F2.17-100%
100%
☆
Chapter 5 Function parameter
31
76. F2.20
Higher limit
corresponding M01
pulse output
0.1-10kHz
10kHz
☆
5-1-5.F3 Group - Start and stop control
No. Code
Parameter name
Setting range
Factory
default
Change
77. F3.00 Start running mode
0: Directly startup
1: Speed tracking restart
2: First DC braking and then
start
0
★
78. F3.01 Startup start frequency
0.00 to 10.00Hz
0.00Hz
☆
79. F3.02
Hold time for start
frequency
0.0 to 50.0s
0.0 s
★
80. F3.03
Braking current before
start
0.0 to 150.0%
0.0%
★
81. F3.04 Braking time before start 0.0 to 50.0s
0.0 s
★
82. F3.05 Stop mode selection
0: Deceleration stop
1: Free stop
0
☆
83. F3.06
Start frequency of stop
braking
0.00 to F0.08 (maximum
output frequency)
0.00Hz
☆
84. F3.07
Waiting time of stop
braking
0.0 to 50.0s
0.0 s
☆
85. F3.08 Stop DC braking current 0.0 to 150.0%
0.0%
☆
86. F3.09 Stop DC braking time
0.0 to 50.0s
0.0 s
☆
5-1-6.F4 Group - V/F control
No. Code
Parameter name
Setting range
Factory
default
Change
87. F4.00 V/F curve setting
0: linear V/F curve
1: multi-point V/F curve
2: square V/F curve
3:1.25th power V/F curve
4:1.75th power V/F curve
0
★
88. F4.01 Torque boost
0.0%: automatic torque boost
0.1% to 30.0%
0.0%
☆
89. F4.02 Torque boost cut-off
0.0% to 50.0% (relative to
rated frequency of motor)
20.0%
★
Содержание CA-203A
Страница 1: ...Vector control inverter Operating manual CA Series www tpg tw com...
Страница 61: ...1 TPG Corp TPG Corp 1 1 1 1 1 1 1 1 1 2 1 2...
Страница 62: ...2 1 2 U V W EMC P RB R S T U V W 3 U V W AC36V 1 3 1 500V 5M 2 3 0Hz 400Hz 50Hz 4 5 PWM...
Страница 63: ...4 6 PWM 7 8 CA 9 CA 10 11 1000m 12 13 14 1 2 3 4 5 15 1 U V W 2 3 4 5 5 6 MOS IGBT 7 E 8 CE 1 4...
Страница 70: ...18 4 7 CA Series K1 K1 K1 R S T MC1 MC2 MC1 MC2 M 3 4 5 19 4 8 4 6 R S T...
Страница 101: ...80 7 1 3 7 3 81 8 1 6 LED OLED 2 1 R S T U V W IGBT 8 2...
Страница 109: ...MODBUS 05H 06H 07H 08H EPPROM...