- 105 -
00504451E
(t)
Connect the discharge hose to the condenser
using a bolt.
Tightening torque
5.4 N•m (55 kgf•cm, 4.0 lbf•ft)
A043961
3: BOLT (M6 25)
1: CONDENSER
4: FRONT
2: DISCHARGE HOSE
(u) Loosely connect the suction hose to the suction
tube No.1 using a bolt.
1: SUCTION TUBE No.1
5: FRONT
A043962
2: SUCTION HOSE
3: BOLT (M6 25)
HAND TIGHTEN
4:
(v) Fully tighten the bolt.
CAUTION
Tightening Torque
9.8 N•m (100 kgf•cm, 7.2 lbf•ft)
1. Keep the distance between liquid tube No.3 and
fuel tube 5 mm or more.
2. Keep the distance between suction tube No.2
and exhaust pipe 10 mm or more.
A043963
9: FRONT
9: FRONT
1: SUCTION TUBE No.2
2: BOLT (M6 20)
FULLY TIGHTEN
3:
5: FUEL TUBE
10 mm OR MORE
5 mm OR MORE
8:
7:
4: LIQUID TUBE No.3
1: SUCTION TUBE No.2
6: EXHAUST PIPE