Diagnostic information
2-87
Fuser service checks
920.xx—Cold fuser service check
Error codes 920.x and 922.xx may display for a cold fuser failure.
Some 920.xx error codes may be cleared by turning the printer on and off and allowing it to complete POR.
CAUTION:
There is a danger from hazardous voltage in the area of the printer where you are
working. Unplug the printer before you begin, or use caution if the printer must receive power in
order to perform the task.
Service tip: Some 920.xx errors can be caused by multiple sheets of paper being fed up to the fuser.
Service tip: Set the Fuser Temperature to NORMAL before starting this service check. In Diagnostics mode,
select
EP SETUP
, and
Fuser Temp
.
Service tip: It may take several minutes for the error codes 920.xx and 922.xx to be displayed after the printer is
turned on.
FRU
Action
1
Fuser lamp
Fuser lamp AC cable
Observe the lamp through the left near side of the printer. It may be
necessary to remove the redrive assembly to observe the lamp
turning on and off. If the lamp does not come on do the following:
• If not previously removed, remove the redrive assembly. See
“Redrive assembly removal” on page 4-74
.
• Remove the fuser assembly. See
“Fuser assembly removal” on
page 4-26
.
• Make sure the correct type of lamp is installed (voltage and
wattage).
• Verify that the fuser to fuser lamp cable is installed correctly to the
fuser top cover assembly. If incorrect, install correctly; if correct,
go to step 2.
2
AC line voltage
CAUTION
: When taking measurements for AC power, observe all
safety precautions.
Check the AC line voltage to make sure it is within operating
specification. If incorrect, inform the customer; if correct, go to step 3.
3
LVPS
CAUTION
: When taking measurements for AC power, observe all
safety precautions.
Unplug the AC line cord from the printer and pull the LVPS out far
enough to access CN1 on the LVPS board (see
“Low voltage power
supply removal” on page 4-54
). Disconnect the LVPS to fuser AC
cable, plug in the line cord, turn the printer on and measure the
voltage between CN1-1 and CN1-3 on the connector (see the
connector locations at
“Low voltage power supply” on page 5-10
).
If incorrect, replace the LVPS assembly (see
“Low voltage power
supply removal” on page 4-54
); if correct, go to step 4.
4
Fuser lamp
Fuser top cover assembly
Fuser connect cable (fuser
to fuser lamp cable)
Check continuity of the fuser to fuser AC cable, fuser top cover
assembly, and fuser lamp by checking the continuity between the two
pins on the fuser lamp AC cable connector:
• If there is continuity, go to step 5.
• If there is no continuity, check the continuity of the fuser to fuser
lamp AC cable. If incorrect, replace the lamp, if incorrect, replace
the fuser top cover assembly.
Note:
If the fuser lamp is replaced, allow the fuser assembly to cool
or a 925.xx error may be displayed.
Содержание e-STUDIO500P
Страница 1: ...PRINTER P N 12G9609 e STUDIO500P ...
Страница 10: ...x Service Manual ...
Страница 15: ...Laser notices xv Japanese Laser Notice ...
Страница 16: ...xvi Service Manual Korean Laser Notice ...
Страница 22: ...1 2 S ervice Manual Configured model The following illustration shows a standard network printer ...
Страница 43: ...Diagnostic information 2 7 ...
Страница 159: ...Diagnostic information 2 123 ...
Страница 160: ...2 124 Service Manual ...
Страница 161: ...Diagnostic information 2 125 ...
Страница 181: ...Diagnostic aids 3 17 ...
Страница 205: ...Pages 3 42 through 3 44 have been removed from this document intentionally Diagnostic aids 3 41 ...
Страница 286: ...Connector locations and connections 5 1 5 Connector locations and connections Connections System board ...
Страница 297: ...5 12 Service Manual ...
Страница 298: ...Connector locations and connections 5 13 ...
Страница 299: ...5 14 Service Manual ...
Страница 301: ...6 2 Service Manual ...
Страница 303: ...7 2 Service Manual Assembly 1 Covers ...
Страница 305: ...7 4 Service Manual Assembly 2 Frame 1 ...
Страница 307: ...7 6 Service Manual Assembly 3 Frame 2 ...
Страница 309: ...7 8 Service Manual Assembly 4 Frame 3 ...
Страница 311: ...7 10 Service Manual Assembly 5 Printhead ...
Страница 313: ...7 12 Service Manual Assembly 6 Paper feed autocompensator ...
Страница 315: ...7 14 Service Manual 4061 xx0 Assembly 7 Paper feed multipurpose feeder ...
Страница 317: ...7 16 Service Manual Assembly 8 Paper feed alignment ...
Страница 319: ...Page 7 19 has been removed from this document intentionally 7 18 Service Manual ...
Страница 320: ...7 20 Service Manual Assembly 10 Integrated 500 sheet paper tray ...
Страница 322: ...7 22 Service Manual Assembly 11 Drives Main drive and developer drive ...
Страница 324: ...7 24 Service Manual Assembly 12 Hot roll fuser ...
Страница 326: ...7 26 Service Manual Assembly 13 Transfer charging ...
Страница 328: ...7 28 Service Manual Assembly 14 Electronics power supplies ...
Страница 330: ...7 30 Service Manual Note ...
Страница 332: ...7 32 Service Manual Assembly 16 Electronics shields ...
Страница 336: ...7 36 Service Manual Assembly 19 Cabling diagrams 3 ...
Страница 338: ...7 38 Service Manual Assembly 20 Cabling diagrams 4 ...
Страница 340: ...7 40 Service Manual Assembly 21 Cabling diagrams 5 ...
Страница 342: ...7 42 S ervice Manual THE FOLLOWING PAGE 7 43 HAS BEEN OMITTED FROM THIS MANUAL INTENTIONALLY ...
Страница 347: ...7 48 S ervice Manual Pages 7 49 through 7 57 of this manual have been omitted intentionally ...
Страница 348: ...7 58 Service Manual Assembly 35 High capacity feeder 1 ...
Страница 350: ...7 60 Service Manual Assembly 36 High capacity feeder 2 ...
Страница 354: ...7 64 S ervice Manual Pages 7 65 thru 7 70 ofthis manual were omitted intentionally ...
Страница 362: ...I 8 Service Manual ...