HYDRAULIC TESTING
9-14
Rev. 000
TX525 Service Manual
If adjustment is needed:
a. Remove the RH control panel cover.
b. Using a 19mm wrench and a 5mm Allen wrench,
adjust the pressure adjustment screw (Fig. 1869
and Fig. 1870):
• Turn the screw clockwise to increase the
pressure
• Turn the screw counter-clockwise to decrease
the pressure.
Fig 1869
PICT-4326
Fig 1870
PICT-4327
8. Start the engine and run at full rpm.
9. Move the loader arm handle so the tilt cylinder is
retracted into the cylinder barrel. Hold the handle
and take the pressure (psi) reading from the gauge
(Fig. 1868).
Fig 1868
PICT-3413
10. Recommended specification is 2400
+
50 psi (165
+
3.4 bar).
11. Release the handle on the loader valve and shut
engine off.
Содержание Dingo TX 525
Страница 1: ...TX525 Service Manual Sitework Systems Form No 492 9195...
Страница 3: ...ii Rev 000 TX525 Service Manual 8 01 10 Revision 000 REVISIONS...
Страница 11: ...x Rev 000 TX525 Service Manual TABLE OF CONTENTS THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 243: ...ENGINE 4 190 Rev 000 TX525 Service Manual THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 263: ...ELECTRICAL 5 20 Rev 000 TX525 Service Manual THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 377: ...HYDRAULIC SYSTEM 6 114 Rev 000 TX525 Service Manual THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 479: ...DRIVE SYSTEM 7 102 Rev 000 TX525 Service Manual THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 533: ...BRAKES 8 54 Rev 000 TX525 Service Manual 12 Install the rear access panel Fig 1836 Fig 1836 PICT 4505a...
Страница 553: ...HYDRAULIC TESTING 9 20 Rev 000 TX525 Service Manual THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 554: ...TX525 Service Manual Form No 492 9195...