72
If the flowmeter has not been used for a long
period of time, the rotor may be sticky. Flushing
the system out with water should make the rotor
spin freely.
Flow rate may be too low to register a reading, or
foreign material may be lodged in the flowmeter.
CALIBRATION FLOW IS INACCURATE:
This may result from an incorrectly-entered
"FLOWMETER CAL" value. The default "FLOW
CAL" number is 919. This number should be fine
tuned as described in the "Fine Tuning Flowmeter
Calibration" section, see page 61-62. Other
causes may be a flow rate too low to register, or
foreign material lodged in the flowmeter.
6553.5 MESSAGE DISPLAYED IN THE RATE
MODE:
If this message appears when you are in motion
with the sprayer on, it indicates that speed sensor
impulses have been lost.
CONSOLE IS ERRATIC IN OPERATION:
If you have a two-way radio, it may be mounted
too close to the console. Keep all Spray Pro
cables, antenna and power cable away from the
radio.
DISPLAYED MEASUREMENTS DO NOT MAKE
SENSE:
The console may be in the incorrect measurement
mode (US or metric).
DISPLAY READS OFL:
CALIBRATION DISTANCE and CALIBRATION
FLOW will read OFL when they have exceeded
their maximum count. Reset to zero to resume
counting. All counters will read OFL if total width
calibration is greater than 65535.
SPRAY PRO
-
TROUBLESHOOTING
All Spray Pro
consoles are tested prior to
packaging, so unless there has been damage in
shipment you can be confident that everything
will be operational when you receive it.
However, if you do encounter a problem that
appears to be related to equipment failure,
PLEASE DO NOT OPEN THE CONSOLE. Your
system is protected by a warranty and TORO will
correct any defect.
CONSOLE APPEARS DEAD:
Using a test light, check for 12 volts at the power
source. Also check for damaged power cable.
(Console requires 12 volts for proper operation).
SPEED IS ALWAYS ZERO OR ERRATIC:
Check for properly established SPEED CAL. The
default "SPEED CAL" number is .91. Check cable
for breaks or incomplete connection.
For more suggestions on solutions to speed
problems, see "Checking Individual Components"
section this page.
CALIBRATION DISTANCE COUNT IS
INACCURATE:
SPEED CAL was incorrectly measured or
entered. The default calibration is .91, review
calibration, readjust and test.
NO READOUT OF APP. RATE OR
CALIBRATION FLOW:
Check to see that the sprayer pump and
equipment are operating properly. If liquid is
moving through the flowmeter, check that the
flowmeter diagnostic light is flashing. For details,
see "Flowmeter Maintenance" section, page 68.
Check to see that a FLOWMETER CAL number
has been entered. Also check cable for breaks
or incomplete connection.