30
NOTE:
For inspection of Neutral Switch, see
Before Operating, page 18.
MAINTENANCE
7.
Replace the Shifter Boot, reinstall fasteners
and tighten securely. Reinstall jam nut and Shifter
Ball.
8.
Reinstall Air Cleaner Cover and tighten
securely.
NOTES:
4. Loosen jam nut on Neutral Switch. (See
Fig. 3, page 29)
5. Rotate Neutral Switch (toward or away from
Actuator) to the position where the Switch Ball is
engaged just enough to close the circuit of the
Switch. The Neutral Switch circuit should be
closed only while the selector is in Neutral. An
easy way to verify this condition is to disconnect
the Neutral Switch plug and connect an electrical
ohm meter to the two terminals inside. Switch
the meter to ohms selection and check for
continuity while changing gear selections.
The
circuit should never have continuity when
the range selector is in any driving gear.
6. When the Neutral Switch is properly
positioned, tighten the jam nut.
PUMP DRIVE GEAR BOX:
1.
Change the fluid in the Pump Drive Gear Box
after the first 50 hours of operation. Use part
number 104-8772 (1 QT.) or Mobil SHC 634
Synthetic Lubricant.
IMPORTANT: Do Not use mineral based gear
oil in the Gear Box. Long term damage will
occur to the internal components.
2.
Drain the fluid and fill to the plug located on
the left-hand side of the Gear Box. Capacity is
approx. .5 quart.
3.
Change the fluid every 400 hours, thereafter
or annually, which ever comes first.