2-37
(4) Material selection
Please select a material, which is the target pipe material.
Table 2.2.7-1 Selectable materials
Selectable materials
Sound speed [m/s]
Carbon Steel
5900
Ductile Iron
5800
Cast-iron
4500
Copper
5010
Stainless Steel
5730
PVC
(Poly Vinyl Chloride)
2280
FRP
2560
Acrylic
2720
User Defined
Input any value
between
500 to 9000
If you would like to another parameter, you can use
“User Defined” item and input any value.
2.2.8 System setting
On this directory, you can set time, meter selection or system conditions.
Select by direction or numeric button, then push
Select
key (F3 button) to enter.
Fig. 2.2.8-1 System setting menu
S y s t e m S e t t i n g
1 :
< T i m e S e t t i n g >
2 : < M e t e r S e l e c t i o n >
3 : < A n a l o g O u t p u t >
4 : < T e m p e r a t u r e I n p u t >
5 : < L C D S e t t i n g >
6 : < L o c a l i z a t i o n >
7 : < D A T A I n i t i a l i z a t i o n >
N o
# 0 1 : 1 0 0 / S t e e l / 1 M
B a c k
S e l e c t
Содержание UFP-20
Страница 1: ...Doc No KF08 002L Portable Ultrasonic Flowmeter UFP 20 Installation Operation Manual ...
Страница 3: ... 2 The attachment of warning label is as follows Fig 1 2 Rear view of main unit Warning label ...
Страница 8: ...1 Installation ...
Страница 9: ......
Страница 17: ......
Страница 18: ......
Страница 91: ......
Страница 92: ......
Страница 93: ......
Страница 130: ...2 Operation ...
Страница 131: ......
Страница 182: ...3 Other ...
Страница 183: ......
Страница 193: ...3 8 3 2 4 Dimensions 1 Main Unit Fig 3 2 4 1 Main Unit Hand Strap ...
Страница 195: ...3 10 1 Adaptor A 2 Adaptor B 3 Knob Fig 3 2 4 5 Fixture 1 Fig 3 2 4 6 Fixture 2 Fig 3 2 4 7 Z path method adaptor ...
Страница 196: ...3 11 4 Large Transducer Kit Fig 3 2 4 9 Fixture 1 Fig 3 2 4 10 Fixture 2 Fig 3 2 4 8 Large transducer ...