
(6)
3. Other
Here you can see concerned with Maintenance, Specification or Measuring Principle.
3.1 Maintenance and Inspections.......................................................... 3-1
3.1.1 Transducer and Main unit maintenance and inspection.................... 3-1
3.1.2 Life of components............................................................................ 3-1
3.2 General Specifications..................................................................... 3-3
3.2.1 Overall Specifications........................................................................ 3-3
3.2.2 Main unit specifications...................................................................... 3-4
3.2.3 Accessories....................................................................................... 3-7
3.2.4 Dimensions........................................................................................ 3-8
3.3 Principles of the Ultrasonic Flowmeter............................................. 3-12
3.3.1 Measurement principles..................................................................... 3-12
3.3.2 Z-path (transmission) and V-path (reflection) methods......................3-15
3.4 Appendix.......................................................................................... 3-16
3.4.1 General condition for straight pipe length.......................................... 3-16
3.4.2 Sound Velocity & Kinematics Viscosity reference list........................ 3-17
3.4.3 Sound velocity (water)....................................................................... 3-19
3.4.4 Pipe Chart.......................................................................................... 3-20
3.5 FAQ.................................................................................................. 3-23
3.5.1 Measurement method........................................................................ 3-23
3.5.2 Measured fluids................................................................................. 3-25
3.5.3 Pipes.................................................................................................. 3-26
3.5.4 Installation location............................................................................ 3-27
3.6 Troubleshooting............................................................................... 3-29
3.6.1 Main unit and components.................................................................3-29
3.6.2 Measurement..................................................................................... 3-31
Содержание UFP-20
Страница 1: ...Doc No KF08 002L Portable Ultrasonic Flowmeter UFP 20 Installation Operation Manual ...
Страница 3: ... 2 The attachment of warning label is as follows Fig 1 2 Rear view of main unit Warning label ...
Страница 8: ...1 Installation ...
Страница 9: ......
Страница 17: ......
Страница 18: ......
Страница 91: ......
Страница 92: ......
Страница 93: ......
Страница 130: ...2 Operation ...
Страница 131: ......
Страница 182: ...3 Other ...
Страница 183: ......
Страница 193: ...3 8 3 2 4 Dimensions 1 Main Unit Fig 3 2 4 1 Main Unit Hand Strap ...
Страница 195: ...3 10 1 Adaptor A 2 Adaptor B 3 Knob Fig 3 2 4 5 Fixture 1 Fig 3 2 4 6 Fixture 2 Fig 3 2 4 7 Z path method adaptor ...
Страница 196: ...3 11 4 Large Transducer Kit Fig 3 2 4 9 Fixture 1 Fig 3 2 4 10 Fixture 2 Fig 3 2 4 8 Large transducer ...