44
HA0365T Rev D Jan 2017
Chapter 5
.
Fig. 5.9 Piezo Driver Settings
11)Make the following parameter settings, as shown in Fig. 5.9
Output Voltage Range -
Set the corresponding voltage for the piezo being
driven
, 75V, 100V or 150V.
Drive Input Source (Open Loop) -
Select
Adjustment Wheel + SW
Analogue Input Source (EXT IN) -
Select
Hub Channel 1
Feedback Loop Mode -
Select
Closed Loop
12)If desired, click the ‘Persist Settings To Hardware’ box. These settings will then be
loaded on each power up cycle.
13)Click ‘OK to save the settings.
Note
To identify the piezo unit associated with the GUI panel, click the ‘Ident’
button; the Power LED on the panel of the asssociated controller flashes
for a short period.
Note
The following parameter settings are shown for example only, and are by
no means the only possible setting combinations.