Fuel System (Rev 1/97)
91
11. Recheck the alignment of the scribe mark and the edge
of the guide plate.
12. Turn the unit off and connect 20 wire to the reset
switch.
13. Reconnect the 8S circuit to the starter solenoid at the
jumper plug near the starter.
14. Remove the cap nut and spacer from the fuel limit
screw.
15. Install the cap nut without the spacer.
16. Install a new lead seal.
17. Install the inspection plate.
Fuel Injection Pump
Removal
1. Remove the inspection plate from the side of the injec-
tion pump housing.
Remove Inspection Plate
2. Remove the clip and disconnect the governor link from
the fuel control rack.
aea344
3. Remove the nuts from the four studs on top of injection
pump.
4. Center the fuel control rack and remove the injection
pump from the housing.
NOTE: The timing shims will usually stay attached to
the injection pump.
Disassembly
NOTE: Prepare containers to keep the various parts for
each cylinder separate. DO NOT mix the parts for one cyl-
inder with parts for another. The steps in this procedure
that describe the components for an individual cylinder
must be performed on the components of each cylinder.
1. Remove the plunger guide stopper pin.
Fuel Injection Pump Assembly
2. Push in on the plunger guide and remove the plunger
guide stopper.
aea345