ULTRA-CUT 200 XT
4-22
OPERATION
Manual 0-5304
CCM Status Code
CCM-Group-5 Gas Controller Communication Port
Code
Message
Remedy / Comments
501
CANBUS Acknowledge Fault
CCM to DMC Fiber-optic Control cable not connected, not properly
connected or cable defective. DMC power supply or Control PCB
defective. Defective CCM, replace.
502
CANBUS Off
Dirt on fiber ends or in connectors; blow out with clean dry air; Fiber
not locked into connector; Sharp bends in fiber; Fiber defective
503
CANBUS Errors Warning
Dirt on fiber ends or in connectors; blow out with clean dry air; Fiber
not locked into connector; Sharp bends in fiber; Fiber defective;
504
Reserved
No information available; Contact customer service
CCM Status Code
Group 6 -- CCM
Code
Message
Remedy / Comments
601
Analog Voltage Error
Defective CCM, replace.
602
ADC or DAC error
Defective CCM, replace.
603
Reserved
No information available; Contact customer service
604
Data Memory error
Defective CCM, replace.
605
Program memory fault
Defective CCM, replace.
606
+5V Logic supply low
Defective CCM, replace.
607
Processor over temperature
Reduce ambient temperature; Defective CCM; replace
608
5V supply for RS 485/422 com-
munication low.
Defective CCM, replace.
609
Firmware Update Device Error
Defective CCM; replace
610
Firmware Update Protocol Error Defective CCM; replace
611
USB Controller Fault
Defective CCM; replace
612
USB Power Fault
Faulty USB device plugged into USB port, remove; Defective CCM
613
USB Log Creation Fault
Unable to create Log file on USB Flash drive last firmware update attempt; Use dif-
ferent USB Flash Drive or Reformat
614
No USF File
File VTCCMFW.USF missing from Flash Drive; Add proper files to Flash Drive for
Firmware Update; Use different USB Flash Drive or Reformat
615
No CCM Update File
CCM Firmware file specified in VTCCMFW.USF not found ; Add proper files to
Flash Drive for Firmware updating
616
DPC Update Fault
Fault occurred attempting to update DPC firmware; Add proper files to USB Flash
drive for Firmware updating; Refer to CCM_LOG.TXT on Flash Drive for details
617
DMC Update Fault
Fault occurred attempting to update DMC firmware; Add proper files to USB Flash
drive for Firmware updating; Refer to CCM_LOG.TXT on Flash Drive for details
618
ADC Calibration Fault
Error too large calibrating ADC; Fault persists defective CCM;
619
Flow Switch Fault
Flow switch reporting coolant flow when pump off;
620
Non Volatile Memory Error
Non Volatile Memory Storage Corrupted and Erased; Fault persists defective CCM.
621
USB Format Fault
A USB flash drive was detected but could not be read by CCM. Backup any files
currently on flash drive, reformat the USB flash drive to a FAT or FAT32 file sys-
tem, replace only the CCM update files and try again. Use different USB flash drive
formatted with FAT or FAT32 file system.
622
CCM Code Execution Fault
Possible EMI noise problem or code fault. Check for proper grounding and bond-
ing of equipment and routing of torch leads and cables to reduce Electromagnetic
Emission Interference onto CCM module. If problem persists, verify CCM code
version is the latest supported revision. Replace CCM module.
Содержание ULTRA-CUT 200 XT
Страница 6: ...This Page Intentionally Blank...
Страница 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Страница 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Страница 142: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 8 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 144: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 9 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 146: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 10 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 148: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 11 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 150: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 12 Display PCB Layout Test Point Test Point Art A 11679...
Страница 151: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 25 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Страница 152: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 13 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 154: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 14 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 156: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 15 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 158: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 16 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 161: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 35 APPENDIX 18 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Страница 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Страница 227: ......