ULTRA-CUT 200 XT
Manual 0-5304
OPERATION
4-11
Art # A-09237
3. Now put the flash drive with the renamed file back into the TSC 3000 and perform the file restore.
4. Go back to the Home screen. You will find your new file name (John Doe’s) and the old name with the same file number
[20392]. They are the same process, either one will work. You can delete the file with the old name if you don’t want both of
them showing.
4.09 Sequence of Operation
Ultracut with DFC 3000 using TSC 3000
The purpose of this section is to explain the steps an operator should follow when using the DFC 3000 with the TSC 3000 touch
screen control panel for a specific cutting process. Also included are steps to follow for changing torch consumables.
NOTE!
For units not using the TSC 3000 where control is embedded into the cutting table
controller most of this sequence still applies except for the parts that are specific to
the TSC 3000. For those sections refer to the cutting table controller documentation.
NOTE!
When the TSC 3000 is installed, J14 on the CCM must be set for 2 Wire communica-
tion. For units not using a TSC 3000, determine if the communication requires 2 wire
or 4 wire communication and set accordingly. The XT iCNC controller requires 4 wire
setting. See section 3.13 and the Appendix.
This assumes the system setup; language and units, lead lengths, etc., have already been performed by the installer and the
system is confirmed as operational.
1. Before Applying power:
a) Ensure that the required gasses are connected to the DMC 3000 inlet and gasses are turned on and set for required
inlet pressure.
b) Ensure you have a torch cartridge with consumables installed on the torch.
If you don’t know what consumables you need to use and need to select the cutting process in order to read the consumables
list on the TSC 3000, you can start up with Plasma Disabled. In this case the operation sequence will skip to step 3.
c) Set Plasma Enable SW on the TSC 3000 to Enabled.
2. Turn on 3 phase power at the main disconnect (Plasma Enable on TSC 3000 on). Turn ON/OFF switch to the ON position (up).
System will then go through the start up sequence.
a) For about 10 seconds the decimal points of the 4 digit display blink from right to left.
b) Next the 4 rectangular LED indicators and the 4 status display digits illuminate all segments as a test.
c) Then for about 6 seconds the display shows the letter “C” (code) followed by the CCM code version. Example “C1.2.0”
. During this time various input voltage tests are being performed. If a fault is found its code is displayed and the start
up sequence halts. Faults will show “E” or “L”. If Plasma hasn’t been Enabled by this point, E101 will be displayed.
If disabled the pump will not start, the gas LED doesn’t blink and the contactors don’t close (steps d & e). However
the events of steps f & g will continue and you can select and load the cutting process. Until the process is loaded,
the display shows “0” indicating no process has been loaded. If a fault exists the display alternates between “0” and
the fault code.
Содержание ULTRA-CUT 200 XT
Страница 6: ...This Page Intentionally Blank...
Страница 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Страница 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Страница 142: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 8 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 144: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 9 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 146: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 10 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 148: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 11 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 150: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 12 Display PCB Layout Test Point Test Point Art A 11679...
Страница 151: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 25 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Страница 152: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 13 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 154: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 14 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 156: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 15 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 158: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 16 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 161: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 35 APPENDIX 18 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Страница 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Страница 227: ......