ULTRA-CUT 200 XT
Manual 0-5304
APPENDIX
A-65
Troubleshooting:
1. If it reports the current of an individual inverter section is too high, the problem is the inverter.
2. If the report is current too low (which included no current) check the connections.
3. The ribbon cable for the first inverter section (IM#1A) must connect to that section only but if there are 2
additional sections, unit is 200A or greater, swap the ribbon cable going into those sections.
a. If it now reports a different section as bad, the one whose cable was moved, then the original section was
bad.
b. If it still reports the original section the ribbon cable or the CCM is bad (unlikely).
c. Swap both ends of the ribbon cable with one next to it. If still reports the original section then the problem
is with the CCM if not then it’s the ribbon cable.
4. If it’s the first inverter section or it’s a 100A unit so there’s no other inverter to swap cables with, replace the
inverter.
Additional hint: Inverter control PCBs have a green LED, D24, PWM ON, that lights when that section is enabled
and has a demand signal. The LED brightness is relative to the output so may be very dim if output is low. If
that LED doesn’t light may indicate a defective inverter (control board).
224
Inverter 1 not found.
There must be an inverter connected in the 1st section, 1A, to be able to pilot. During the power up sequence,
before power is connected to the inverters, the CCM does a continuity test to see if its section 1A ribbon cable
(J31 on CCM) is connected.
Causes & troubleshooting:
• As this is just a continuity test it is very unlikely to be a bad inverter. Most likely a poor connection or
defective ribbon cable.
o Check ribbon cable connections at both ends of INV1A to CCM J31 (1A) cable. Make sure it is plugged
into J31, the top connector, on the CCM.
o Plug a different inverter cable into J31, doesn’t matter which one for this test as long as it’s plugged
into an inverter on the other end. If still gives 224, “Inverter 1 not found” fault, it’s a bad CCM. Oth-
erwise it’s the ribbon cable.
225-230 Inverter Revision and CCM incompatible.
If sometime in the future we should make a change to the inverter making it incompatible with older CCM we
have included a hardware key that would change to indicate this. During the power up sequence, before power
is connected to the inverters, the CCM does a continuity test to determine what is the hardware key configura-
tion. The key uses 3 lines of the CCM to inverter ribbon cable which are named IS_ID_A, IS_ID_B, IS_ID_C (on
pins 12, 13 & 14) and checks for continuity to a 4th line OUTCOM (pin 9). The test consists of applying voltage
to OUTCOM and looking for that voltage coming back on the 3 ID pins. The present configuration has all 3
lines connected to OUTCOM so all 3 should be high.
To get the 225-230 code now when we don’t have any incompatible revisions would most likely be a bad con-
nection in the ribbon cable between the CCM and the inverter or a defective CCM (unlikely).
• On the inverter section swap the ribbon cable with that of a different inverter section. If fault remains
unchanged, still calls out the original inverter section, the problem is with either ribbon cable or CCM.
• On the inverter end put the ribbon cables back in their original positions. Now swap suspect ribbon
cable with another one on the CCM. If the fault now moves to a different section it’s the ribbon cable. If
it remains with the original section the problem is the CCM.
Содержание ULTRA-CUT 200 XT
Страница 6: ...This Page Intentionally Blank...
Страница 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Страница 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Страница 142: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 8 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 144: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 9 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 146: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 10 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 148: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 11 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 150: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 12 Display PCB Layout Test Point Test Point Art A 11679...
Страница 151: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 25 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Страница 152: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 13 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 154: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 14 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 156: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 15 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 158: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 16 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 161: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 35 APPENDIX 18 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Страница 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Страница 227: ......