ULTRA-CUT 200 XT
A-64
APPENDIX
Manual 0-5304
210–211 Output current, measured by the work lead current sensor, is too high (210) or too low (211).
These are warnings and do not shut down the process but may explain poor cut quality or poor parts life.
Individual inverter sections have their own current sensors and the work lead has a current sensor whose
signal should equal the sum of the individual inverter sections. Each section is set to output a certain current
based on its ”demand” signal. If the current differs from the total “demand”, sum of the individual demands,
the individual sections are checked to determine if their output is correct compared with their demand signals.
If the individual sections are correct but the work current sensor signal differs from the total demand by more
than 16% code 210 (too high) or 211 (too low) is displayed.
If an individual inverter section was found to be in error causing the total current to be wrong, a different code
would be displayed in the range of 212 to 223 depending on which section was at fault.
Possible causes for work current signal too high:
• HCT1 Work Current Sensor
• Relay PCB
• CCM
Possible cause for work current to low.
• All the above plus a short to chassis caused by:
o User installed equipment connect behind the current sensor that makes a connection to work or earth
allowing current flow to bypass work sensor.
o In output shorted to chassis.
Troubleshooting:
1. For current too low due to a short disconnect work lead from back of unit. Check for continuity to chassis,
there should be none. Inspect for incorrectly connected user equipment.
2. If no shorts were found or if fault was current signal too high see section on code 207 for detailed description
of the power and signal paths for the work lead current sensor.
3. In the section on code 207 for Relay PCB it describes measuring the work current sensor signal when there
is no current. The signal should be zero and we assume it is or else you should have gotten the 207 code. If
the zero current signal is correct but there is an error while cutting, measure the signal on the 40pin ribbon
cable (Relay board J4 to CCM J23) pins 27 (-) & 28 (+). The signal voltage should equal the cutting current
* 0.0266. For example for 100A (100*0.0266) =2.66V.
• If this signal is correct the fault is the CCM
• If it’s not correct the error may be in the Relay board or sensor. Follow the instructions for code 207 to
measure the voltage to and signal from the current sensor at J1 on the Relay board. The signal voltage
should equal the cutting current * 0.0133. For example for 100A (100*0.0133) =1.33V. For 400A would be
400*0.013 3= 5.33V.
• If power and signal are correct Relay board is faulty. If not correct the HCT1 work current sensor is bad.
212-223 Incorrect output from an inverter section.
Work current high or low due to wrong output from one inverter section. Individual code indicates which section.
Causes may be:
• The named inverter section output connector, J102 A or B, is not plugged in or is damaged.
• Ribbon cable with bad connection, perhaps not fully locked in place at either the inverter or the CCM.
• Defective inverter section.
Содержание ULTRA-CUT 200 XT
Страница 6: ...This Page Intentionally Blank...
Страница 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Страница 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Страница 142: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 8 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 144: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 9 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 146: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 10 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 148: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 11 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 150: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 12 Display PCB Layout Test Point Test Point Art A 11679...
Страница 151: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 25 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Страница 152: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 13 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 154: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 14 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 156: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 15 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 158: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 16 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 161: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 35 APPENDIX 18 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Страница 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Страница 227: ......