ULTRA-CUT 200 XT
Manual 0-5304
APPENDIX
A-71
Possible causes:
• Cooling fan(s) not operating.
• Disrupted air flow.
• Defective inverter module.
• Inverter Ribbon cable bad connection.
• Defective CCM.
Originally 100 and 200A units had 2 smaller fans while 300 & 400A used a single larger fan along with a larger
radiator. More recently, the single larger fan may be used in the 100 & 200A as well. Replacement fans for all
units are a single fan kit.
Troubleshooting:
1. Confirm that air is exhausting from both the top (top fan)and bottom (bottom fan of units with 2 fans) of the
opening in the right side panel. As the fan(s) are behind the radiator it’s hard to see them to confirm they
are turning but perhaps you can use an inspection mirror. Refer to section for code 403 for troubleshooting
defective fans.
!
WARNING
Fan blades can be moving and accidental contact with a mirror or other
inspection devise can cause personal injury or damage to the machine.
2. Leaving the side panels and cover off, especially the left lower side or the top cover will reduce the air flow.
Also if the radiator fins become clogged with dust it will reduce air flow. Clean the radiator periodically by
blowing air into it to clear dirt from the fins.
259-264 Inverter Over Temperature due to high Ambient.
The CCM measures the ambient temperature where the cooling air enters the louvers on the left side of the
front panel. If an inverter goes over temperature and we have determined that the ambient exceeds 40 deg C
we will get one or more of the high ambient codes, 252-264. The sensor, TS2, is a NTC (Negative Temperature
Coefficient) resistor whose resistance varies with temperature. It is mounted on the inside of the front panel
next to the louvers on the left. To access it requires removing one or more of the inverter modules. If the ambi-
ent is high but no inverter is too hot there is no fault.
Possible causes:
• Ambient is too high.
• Cooling fan(s) not operating.
• Disrupted air flow.
• TS2, Ambient temperature sensor, shorted (very unlikely) or otherwise defective.
• Defective Relay board.
• Defective CCM.
• Defective Relay board.
Troubleshooting:
1. If room temperature exceeds 40 deg C, cool the room, or operate the unit at reduced duty cycle or lower
current.
2. Confirm that air is exhausting from opening in the right side panel. As the fan(s) are behind the radiator
it’s hard to see them to confirm they are turning but perhaps you can use an inspection mirror. Be careful
not to get the mirror or your hands into the blades. 100 & 200A units have 2 smaller fans, 300 & 400A have
one larger one.
3. It is unlikely these high ambient temperature codes would be set before some other temperature related code
but just in case we’ll note that leaving the side panels and cover off, especially the left lower side or the top
cover will reduce the air flow. Also the radiator fins clogged with dust will reduce air.
Содержание ULTRA-CUT 200 XT
Страница 6: ...This Page Intentionally Blank...
Страница 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Страница 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Страница 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Страница 142: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 8 CCM CPU PCB Layout Test Point Test Point Art A 11675_AB...
Страница 144: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 9 CCM I O PCB Layout Test Point Test Point Art A 11676_AC...
Страница 146: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 10 Pilot PCB Layout Art A 11677 Test Point Test Point...
Страница 148: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 11 Relay and Interface PCB Layout Test Point Test Point Art A 11678_AB...
Страница 150: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 12 Display PCB Layout Test Point Test Point Art A 11679...
Страница 151: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 25 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Страница 152: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 13 System Bias PCB Layout Test Point Test Point Art A 11680...
Страница 154: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 14 Main Inverter Bottom PCB Layout Test Point Test Point Art A11681_AB...
Страница 156: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 15 Main Inverter Top PCB Layout Test Point Test Point Art A11682_AB...
Страница 158: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 16 Control and Fault PCB Layout Test Point Test Point Art A11683_AB...
Страница 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Страница 161: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 35 APPENDIX 18 Cap Bias Top PCB Layout Art A 11686_AB...
Страница 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Страница 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Страница 227: ......