The RES-11XR3 contains five high-speed 38-mm fans, each of which can be “hot-
swapped” in the field in the event of a fan failure.
2.1.6.1 Removing and Installing a 38-mm Fan
Perform the following steps to remove and install a 38-mm fan:
1.
Push the fan lid lock left to unlock the fan lid (see
Figure 2-16
on page 2-19).
Pull the fan lid upward exposing the five 38-mm fans.
2.
Each fan is secured by a fan lock located on top of the fan. To remove a fan,
push the fan lock toward the front of the fan and pull the fan directly upward
(see
Figure 2-17
on page 2-19).
3.
When the fan is removed, its 3-wire connector will automatically be discon-
nected from the chassis. Insert the replacement fan carefully into the empty
fan slot until it is flush with the other fans. The 3-wire connector will automat-
ically engage its counterpart successfully.
Note:
Since RES-11XR3 fans are “hot-swappable”, it is not necessary to turn off
system power in order to remove and replace a fan,