NBC™ Flat Belt - IOM
P/N: 1118140
Rev: 07/29/2020
Page
84
of
129
Extension Cables
The following extension cables are available to meet application requirements where longer zone
lengths or skipped zones must be accommodated. Each cable has 4 conductors, with male and
female 2X2 connector ends.
Part Number
Description
1117372
CABLE,CTRLS-EXT-39"-2X2 MALE-FEMALE
1117373
CABLE,CTRLS-EXT-78"-2X2 MALE-FEMALE
1117374
CABLE,CTRLS-EXT-157"-2X2 MALE-FEMALE
Table 13: Extension Cables
Discharge Logic Control
Discharge Logic Control refers to using a standard Logic Assembly set to Basic Logic mode to control
the release from the last discharge zone of a length of CRUZcontrol. This is typically done when
CRUZcontrol conveyor (of any kind) feeds non-CRUZcontrol conveyor. There are no air connections
made to the valve section of the Logic Assembly. When used this way, the added Logic Assembly is
known as the Discharge Logic Assembly (DLA).
The Discharge Logic Assembly is mounted on the charge end of the conveyor immediately
downstream of the last (discharge) zone of a length of CRUZcontrol accumulation conveyor. It is
connected to the Logic Assembly of the discharge zone as shown. There is no need for a Function
Module to be attached to it. The DLA does not need to be given a release signal. Product blocking
that photoelectric sensor will stop release from the CRUZcontrol discharge zone, until the
photoelectric sensor clears again. This operation can usually be left enabled and ready to function
regardless of whether the receiving conveyor is running or off. There would be no need to interface
the CRUZcontrol operation with the receiving conveyor operation, since the functioning of it is based
solely on product movement.