NBC™ Flat Belt - IOM
P/N: 1118140
Rev: 07/29/2020
Page
81
of
129
One Power Supply used to power two separate CRUZcontrol sections
This drawing illustrates the use of one power supply to power two separate, short CRUZcontrol
sections on two different conveyors. A second "T" cable is required to connect the second
CRUZcontrol section to the power supply. This can be done to make better use of the full capacity of
a power supply.
It could be necessary to extend the T Cable leads to reach the power supply location. This should be
done with a wire gauge large enough to prevent noticeable voltage drop. The number of CRUZcontrol
zones that can be connected per string must also be reduced based on the voltage drop of the wire
used.
The brown lead on the “T” Cable connects to +24 VDC on the power supply. The blue lead on the “T”
Cable connects to 0 VDC on the power supply.
Figure 9: Two Separate CRUZcontrol Sections