1.6: D
EFINITION OF
T
ERMS
Logic Assembly
The logic assembly is used to setup the type of automatic accumulation of product on the conveyor.
ATB
Air-to-brake (Type of Logic assembly used in NBC conveyors – Normally Open Valve)
Function Module
The function module provides electrical isolation for external signals used to control a CRUZcontrol
system.
Downstream or Upstream
In this manual, it is always in reference to product conveyor flow.
OFF
Off indicates a logical low signal and/or no power. For example if a logic line is OFF, there is no power
on the logic line.
ON
On indicates a logical high signal and/or powered. For example if a slug line is ON, then there is
power on the slug line.
Zone status
The zone is considered full if the local zone’s sensor detects a package. The zone is empty if it does
not detect a package
JP#, #-#
JP stands for “jumper terminal” and the number indicates which jumper terminal is being referenced.
The “#-#” refers to the pins that are connected by the actual jumper. NC means the jumper is not
connected to any terminal.
Ex. jumper terminal #1 pins 1 & 2 (JP1, 1-2)
TB#, #-#
TB stands for “terminal block” and the number indicates which terminal block is being referenced. The
“#-#” refers to the pins that are being used on that terminal block.
Ex. terminal block #1 pins 1 & 2 (TB1, 1-2)