NBC™ Flat Belt - IOM
P/N: 1118140
Rev: 07/29/2020
Page
20
of
129
Solenoid valve
The Solenoid Valve Kit is controlled by an
external signal from the primary control
system supplied by the purchaser. The
Solenoid Valve Kit is typically mounted
near the last NBC contact accumulation
zone prior to the upstream NBC Air Transportation conveyor. The valve is normally open when no
signal is present, which causes the NBC Air Transportation conveyor to stop or accumulate. When the
last NBC Contact Accumulation zone clears, a control signal triggers the Solenoid Valve to activate
(close or stop the air flow) and the NBC Air Transportation conveyor will activate and convey the
product downstream. Review the detail above to determine correct Pilot or Solenoid Valve Kit on the
NBC Contact Accumulation conveyor flow.
Item# Description
1206186 KIT,CPART-SOL VALVE-24V-NBC AIR TRANS-VALVE OPEN
1206187 KIT,CPART-SOL VALVE-110V-NBC AIR TRANS-VALVE OPEN
Solenoid Valve