How to use Immediate Trigger
Use the following command in your PC terminal to set the internal immediate trigger.
TRIGger:SOURce IMMediate
C. Single Trigger Mode (Front panel operation only)
Definition
Single trigger mode takes one reading (or specified number of readings) each time
when user presses TRIGER key. (Please refer to 3.2.3 for setting the number of
samples on each trigger.) When the TRIG annunciator on the display is lit, the meter
is ready for next trigger event. The single trigger mode is only available through the
front panel operations, but it
’
s not available for the diode and continuity functions.
How to use Single Trigger
1.
Press one of the measurement function keys to select a measurement function as
shown in
Figure 3-19
.
2.
Press TRIGGER key on the front panel to set the trigger mode.
3.
Disable the mode by pressing SHIFT + TRIGGER.
Figure 3-19