50
3.1.7 Sensor Selection for Temperature Measurements
The multimeter supports both thermocouple and RTD. User needs to configure the
multimeter for the right sensor type before they can make temperature
measurements.
RTD
Definition
If you are using RTD, the options are: PT100, D100, F100, PT385, PT3916,
user-defined RTD, NTCT and SPRTD. If you need to change the factors that are used
to calculate the temperature in RTD, choose user-defined RTD in which you are able to
change any factors as you wish. The default factors used are listed in
Table 3-3
:
Table 3-3
Type
Alpha
Beta
Delta
R-zero
PT100
0.003850
0.10863
1.49990
100
Ω
D100
0.003920
0.10630
1.49710
100Ω
F100
0.003900
0.11000
1.49589
100Ω
PT385
0.003850
0.11100
1.50700
100Ω
PT3916
0.003916
0.11600
1.50594
100Ω
NTCT
0.003850
0.10863
1.49990
100
Ω
Here is the temperature equation that is used to determine the RTD temperature:
When
C
t
0
:
(
)
100
1
3
2
0
−
+
+
+
=
t
Ct
Bt
At
R
R
t
When
C
t
C
630
0
:
(
)
2
0
1
Bt
At
R
R
t
+
+
=
Where:
+
=
100
1
A
4
10
−
−
=
B
8
10
−
−
=
C
Содержание DL-1060
Страница 1: ...INSTRUCTION MANUAL 6 1 2 DIGITAL MULTIMETER DL 1060 DL 1060G DL 1060VG DL 1060R DL 1060VR B71 0180 31...
Страница 91: ...85 3 4 10 Self test Notice Do not use SELF TEST since it is used only for an after sales service operation...
Страница 146: ...7F Towa Fudosan Shin Yokohama Bild 2 18 13 Shin Yokohama Kohoku ku Yokohama Kanagawa 222 0033 Japan http www texio co jp...