47
3.1.5 Range (Manual & Auto)
Definition
When making measurements except CONT, DIODE, TCOUPL, and Temperature,
DL-1060 will automatically choose a range for you, or you can select the appropriate
range manually. The difference between auto-range and manual-range is the settling
time. Auto-range is a convenient way for you, but manual-range can usually speed up
the process.
If
the input signal is beyond allowed range, an “OVLD” message will be shown on the
display. The threshold of maximum/minimum readings for each range are 120 % of
the range for maximum and 10% of the range for minimum.
Default
The default is auto-range. The manual selected range is stored in volatile memory and
the default will be restored when the meter is power-off. Please refer to
Table 1-1
on
chap.
“
Factory Default When Power-ON
”
.
How to set the auto/manual range:
You can set the auto/manual range either through the front panel operation as shown
in
Figure 3-9
or through the remote interface operation.
Front Panel Operation
1.
Choose a measurement function.
2.
Press SHIFT + ESC button to select auto-range feature. Or use
△
and
▽
buttons
to manually select a range(MAN anounciator will lit when manually selecting a
range).
Figure 3-9
Remote Interface Operation
Use the following commands from your PC terminal to set the range:
CONFigure:<function> <range>,<resolution>