valve
there is the pneumatic oscillating knife
cutting tool, the pressure is 0.8MPa
Check air pressure valve
Make sure that there is no water in it
Check the screws on the
cutter head and tools
Make sure that no screws loose or lost
Clean the felt surface
Use air gun clean it, make sure that there
is no sundries or bumps on it
Week
Check the X and Y limit
sensor
Confirm the sensors are no loose and no
dust
Check bearings conditions
Confirm no bearings loose
Check cable and wires
Confirm whether they are connected firmly
Clean the distribution box
Clean it with the vacuum cleaner
Month
Check the belts
Confirm the belts tightness and wear
Confirm
the
usage
of
consumables
Confirm the usage of consumables
Check the circuit-breaker
Press the yellow button on the circuit
breaker to see if it can work normally
Note:Check the wearing condition of felt irregularly, repair the
damaged part of felt to avoid the joint degumming, resulting in
abnormal cutting.