Premier Elite Series Installation Manual
Global Options
INS176-15
75
Monitor Hardware
E o elec:
loal pions
loal pions
onio Hadae
loal pions
yse ies
onio Hadae
ah als
ell ape
ell ape
y
3
y
y
n
n
The control panel monitors many inputs for fault conditions i.e. the
panel lid tamper, bell tamper, aux fuse etc.
Each one of these options can be disabled to overcome problems
related to the devices being monitored.
P - ATS Path Faults
The Alarm Transmission System is monitored for faults.
A - AC Power Failure
The AC Mains is monitored for faults.
O - Power Outputs/Charger
The Power outputs and charger are monitored for faults. see page
122 for the list of Power Outputs monitored)
B - Bell Tamper
The external sounder tamper loop is monitored for faults.
A - Aux Tamper
The auxiliary tamper loop is monitored for faults.
L - Panel Lid Tamper
The control panel lid tamper is monitored for faults.
B - Battery Faults
The battery is monitored for faults.
Control Timers
E o elec:
loal pions
loal pions
yse ies
onol ie a
is n a 3:
loal pions
onol ies
onol ie a
is n a 3:
onol ie a
is n a :
ie a n ays
ie a n ays
onol ie a
is a :
iea ays
iea ays
onol ie a
is a :34
y
4
y
y
1
y
y
1
y
The
48
has 4 control timers and the
88
,
168
and 640
have 8 control
timers. Each timer has two ON and OFF times (a & b), and can be
programmed to operate on any day of the week. Once configured, the
timers can be used to arm or disarm areas, lockout users and control
outputs.
When programming the Control Timers ON time, pressing
C
will bring a ‘*’ up on the display. This ‘*’ indicates that
the internal sounders will chime every time the Control Timers
ON time is reached.
When programming the Control Timers DAYS of operation,
pressing
8
will bring ‘HO’ up on the display. This ‘HO’
indicates that the control timer will operate on any
programmed Holiday date.