Engineer Utilities
Premier Elite Series Installation Manual
130
INS176-15
Log Event
Description
PROG. START
An Engineer code has been entered
PSUac ## Alarm
An expander input programmed as PSU Monitor control panel has detected an AC Mains failure
PSUbat## Alarm
An expander input programmed as PSU Monitor control panel has detected a Battery fault
PSUvol## Alarm
An expander input programmed as PSU Monitor control panel has detected a 12V Output failure
PSUTam## Alarm
An expander input programmed as PSU Monitor control panel has detected a Tamper condition
QUICK Armed
Quick Arm from keypad #,#
R/Bat ## Alarm
The Wireless receiver has detected a low battery signal from device ##
Radio Jamming
The Wireless receiver has detected an attempt to jam its radio signal
RADIO PAD LOST
The Radio-Pad has no signal or has lost communications with the control panel
REARM LOCK ###
Zone ### has locked out after reaching its re-arm limit (after causing an alarm)
RECENT Armed
Area ? has been armed recently
Redcare Line Fault
The Redcare has detected a line fault
REMOTE Armed
Area ? was armed using the
Wintex UDL
software
REMOTE Disarmed
Area ? was disarmed using the
Wintex UDL
software
Remote PC Reset
A reset has been performed by the remote download PC
Remote Reset
A reset has been performed using the ‘Remote Reset’ input
Redcare Reset
A reset has been performed by the Redcare
RF Device ###Low Battery
RF Device ### has registered a low battery condition
RKP #,# MEDICAL
A Medical alarm (7 & 9) has occurred from keypad number #,#
RKP #.# FIRE
A Fire alarm (4 & 6) has occurred from keypad number #,#
RKP #,# AUD PA
An Audible PA alarm (1 & 3) has occurred from keypad number #,#
RKP #,# SIL PA
A Silent PA alarm (1 & 3) has occurred from keypad number #,#
RKP #,# Tamper
The cover of keypad #,# has been removed
RKP #,# LOST
Keypad ## has been lost from the network
RKP LOCKED #,#
Keypad #,# has been locked out from too many invalid key presses
Site Data Changed
Site Data has been changed e.g. zone ### has been changed
Supervision Fault
A Radio device has failed to poll back to the panel within the Supervision Time
System Over Voltage
The control panel Bell Fuse has failed
TAG ##
User ## has presented their Prox TAG
Test Call Passed
Manual or Periodical Test Call has passed
Test Call Failed
Manual or Periodical Test Call has failed
TESTED ###
Zone ### has been tested
TEST FAIL ###)
Zone ### has failed its Soak test
TAG System Exit (Batt. OK)
The system has been put in to exit via tag and battery voltage is ok
TAG System Exit (Batt. Low)
The system has been put in to exit via tag and battery has low voltage
TAG System Entry (Batt. OK)
The system has been put in to entry via tag and battery voltage is ok
TAG System Entry (Batt. Low)
The system has been put in to entry via tag and battery has low voltage
TIME Armed
Area ? was armed automatically using one of the control timers
TIME CHANGED
The control panel Date has been changed
TIME Disarmed
Area ? was disarmed automatically using one of the control timers
TUBE ### Alarm
Zone ### (programmed as Key Tube) has caused an alarm
USER ##
User ## has entered their code
User Ack
A user has acknowledged a fault to set system
USER CODE CHANGED
A User code has been altered
USER ADDED
A User code has been added
USER DELETED
A User code has been deleted
User Reset
A reset has been performed using a User code
WALK Test Start
The Walk Test mode has been initiated
Zone ### Alarm
Zone ### has been activated
Zone ### Tamper
Zone ### has caused a Tamper alarm
Zone ### Restore
Zone ### has restored to its normal condition
Zone ### Omitted
Zone ### has been omitted
Zone ### Un-Omit
Zone ### has been reinstated
Zone ### Test Start
Zone ### has been put on test
Zone ### Test End
Zone ### has been removed from test
Zone ### Fault
Zone ### has generated a Fault Condition
Zone ### Masked
Zone ### has been Masked