![Texecom PREMIER 168 Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/texecom/premier-168/premier-168_installation-manual_1097225062.webp)
Area Programming
Premier Elite Series Installation Manual
62
INS176-15
Arming Modes
E o elec:
ea ogaing
ea ogaing
ing odes
ea y:
ied ei
ea y:
Eny/Ei
ea y:
ied ei
ea ogaing
ies
y
1
y
y
1
The way that an area arms can be configured for any of the following
options:
1 - Entry/Exit
The area will arm after the ‘Entry/Exit’ door has been closed and the
‘Exit Settle’ timer has expired.
2 - Exit Term.
The area will arm after the ‘Entry/Exit’ door has been closed, the ‘Exit
Terminator’ button has been pressed and the ‘Exit Settle’ timer has
expired.
3 - Timed Exit
The
area will arm after the programmed ‘Exit Time’ has expired.
If an ‘Exit Terminator’ zone is activated at any point during the
exit mode, any remaining exit time is cancelled and the area
will arm immediately.
4 - Instant
The area will arm instantly.
5 - Deferred
The area will arm after the programmed ‘Exit Time’ has expired.
However, if any zones not on the exit route are activated during the
exit mode, the ‘Exit Time’ is restarted.
Area Arm Suites 24/48/64/88/168
E o elec:
ea ogaing
ea ogaing
ea ies
ea ogaing
ies
ea ie
ea ie 4
ea ie 4
<
ea ie 4
<
y
4
n
3
y
y
2
The
24
has 2 Area Arm Suites the
48/64
has 4 Area Arm Suites the
88
has 8 Area Arm Suites the
168
has 16 Area Arm Suites. Any number
of areas can be assigned to each suite. Areas assigned to an Area
Arm Suite will be armed when the suite is selected, making it easier
for the user to select multiple areas if required.
Example
Area Arm Suites could be useful in a domestic situation where the
user wants to arm areas A and B at night but does not want to select
each area individually.
•
Areas ‘A and B ‘ would be assigned to ‘Area Arm Suite 1’
•
When the user wants to arm the system at night, ‘Area Arm Suite
1’ would be selected
•
Areas A and B are automatically selected for arming
Descriptive text may also be assigned to the Area Arm Suite
(see page 63 for details).
Area Arm Suite Controller
The suites can be assigned to keypads so that different combinations
of areas can be armed or disarmed depending on which keypad is
used (see page 80 for details) and operates as follows:
•
Keypad 1 = Area Arm Suite 1, Keypad 2 = Area Arm Suite 2,
Keypad 3 = Area Arm Suite 3 etc.
•
When a User code is entered at a keypad, one of the ‘Area Arm
Suites’ is selected (depending on which keypad was used) and
the areas contained within that suite arm using the arming mode
for that suite, the keypad sounder will also follow the areas
defined by the suite.