Premier Elite Series Installation Manual
Ricochet Learn
INS176-15
143
5.11
Ricochet
Learn
Learning Devices
Learn Devices from first power up
Follow the instructions given on page 48 for first power up of the system.
When the "Confirm Devices" menu appears check and make sure all installed Keypads and Expanders are showing; press
y
/
y
and
y
/
y
again to confirm.
Providing the system has a
Ricochet
enabled expander installed, the following will appear. The flow diagram shows the procedure to learn
devices:-
E o elec:
ean icoche
y
y
ean eice?
Zone ??? ?E??
oe p eice
?E??? s
ean eice o
Zone ??? ?E??
y
y
y
y
y
y
n
n
U
N
N
When all device slots have been used the following screen will be
shown
ll eices
ean
Pressing the
N
/
N
key will return you to the
Ricochet
learn menu; pressing the
R
/
R
key will enter the Delete
devices menu.
Commissioning
Once all devices are learnt they should be installed in their locations starting closest to the expander and working to furthest away. To start
commission mode the receiver should be in Tamper, or in the case of the -
W panels place the jumper on “Fit for Commission” position.
Wait for at least 15 minutes and the test all devices.
Access the Learn Menu using the Omit “Hot” k
ey
From any top level engineering menu pressing the
B
/
key will take you to the
Ricochet
learn menu above.
Menu
B
/
Ricochet
Learn Menu
E o elec:
????????????????
B
/
E o elec:
ean icoche
IMPORTANT
In all cases when entering the Learn menu the next available free Zone will be chosen to learn a device too. It will not be possible to learn a device
to a Zone that already has a device learned too it. The number of expander’s on the system will dictate which next “free” zon
e is chosen to learn
too.
Auto Zone Type & Area
When learning devices, if no editing has taken place of the control panel onboard hardwired zones, these will be switched to Not Used after the
first
Ricochet
®
device is learned to the system; the following defaults will be used for
Ricochet
®
devices learned to the system.
Zone
Type
Area
001-008
Not Used
N/A
009
Entry/Exit 1
A
010
Guard Access
A
011 & above
Guard
A
IMPORTANT
If any editing of any of the on board control panel zones is carried out
BEFORE
any
Ricochet
devices are learned too the system, the control
panel zones will remain at factory defaults.