Installation
Premier Elite Series Installation Manual
28
INS176-15
Expander Outputs
The zone expander has eight programmable outputs, which can be
used to drive auxiliary devices such as LED’s, sounders or relays etc.
Wire as per Panel Outputs shown on page 35 (see page 83 for
details). The electrical characteristics for the outputs are shown
below:
Outputs
Max Current
Type
1 to 8
100mA
Switched -ve
Expander Speaker Output
The expander has an output that can be used for driving up to one 16
or two 8
loudspeakers (see page 34 for details).
Expander Com Port
The Com Port can be used to connect a
PSU200
or a monitored
power supply.
Expander Lid Tamper
The lid tamper of each expander can be disabled if required by fitting
a jumper link across the centre and right hand pins of the ‘Enable
Tamper’ pins (JP2) leaving the left hand pin free. These pins are
located to the left of the address DIL switch just beneath the fuse.
iProx Module
iProx Layout
Options
1
ON
2 3 4
1
ON
2 3 4
Address
R
T
E
N
/C
N
/O
C
o
m
+
T
R
S
p
k
+
D
0
D
1
C
1
L
1
-
C
2
L
2
-
L
+
Tamper
E
x
t
C
o
il
R
em
o
te
L
E
D
’s
R
el
a
y
1
E
x
t
In
t
E
x
t
In
t
Internal Sounder
Off
On
Connection
The
iProx Module
is connected to the network terminals located at
the bottom of the control panel (see pages 20 & 22 for details).
Addressing
The
iProx Module
is addressed as a keypad and will occupy a
keypad slot on the network. The unit must have a unique address,
which must not conflict with keypad or any other
iProx Module
on
the same network
The following table shows the addressing:
Address
DIL 1
DIL 2
DIL 3
DIL 4
1
On
or off
Off
Off
Off
2
4
3
1
2
Off
On
Off
Off
2
4
3
1
3
Off
Off
On
Off
2
4
3
1
4
Off
Off
Off
On
2
4
3
1
5*
On
Off
Off
On
2
4
3
1
6*
Off
On
Off
On
2
4
3
1
7*
Off
Off
On
On
2
4
3
1
8*
On
Off
On
On
2
4
3
1
Never set two modules on the same network to the same
address.
*88/168 & 640 only
Refer to the
iProx Module
manual for programming and operating
instructions.
6
0iXD
Zone Expander
The
60iXD
expander provides the following facilities:
•
Two iD loops each supporting up to 30 biscuits
•
Fused 12V output for powering detectors
•
Engineer’s keypad port for local iD diagnostics
OP16
Output Expander
Output Module Layout
Connecting Output Modules
Output modules are connected to the network terminals located at
the bottom left hand corner of the control panel (see pages 20 & 22
for details).
Output Module Addressing
Each output module must be assigned a different address using the
DIL switches located in the centre of the PCB.
The table below shows the expander addressing:
Address
DIL 1
DIL 2
DIL 3
DIL 4
1
On
or off
Off
Off
Off
2
4
3
1
2
Off
On
Off
Off
2
4
3
1
3*
Off
Off
On
Off
2
4
3
1
4*
Off
Off
Off
On
2
4
3
1
5 **
On
Off
Off
On
2
4
3
1
6 **
Off
On
Off
On
2
4
3
1
7 **
Off
Off
On
On
2
4
3
1
8 **
On
Off
On
On
2
4
3
1
*
88
and
168
only
**
168