www.ti.com
G ND 1
A1
A2
A3
G ATE
B1
B2
B3
1 0 0 K
0 .1 u F
D VDD3 3
DVD D1 5
TC I6 4 8 2 RG MDCL K
TCI6 4 8 2 R G MDIO
2 .5 V/3 .3 V MDC L K
1 5 0
1 5 0
2 .5 V o r 3 .3 V
2 .5 V/3 .3 V MD IO
SN7 4 TVC3 3 0 6
9.12 UTOPIA
9.12.1
Configuration of UTOPIA
Peripheral Section
Figure 13. HSTL to LVCMOS Translation
Documentation for UTOPIA:
•
TMS320TCI648x DSP Universal Test & Operations PHY Interface for ATM 2 (UTOPIA2) (SPRU726)
•
TCI6482 System Boot
•
TCI6482 IBIS Model File
•
Using IBIS Modes for Timing Analysis (
SPRA839
)
The Utopia interface is multiplexed with EMAC MII interfaces (except RGMII). So if Utopia is enabled, only
the RGMII interface is available for EMAC. Some Utopia address lines are multiplexed with PCI signals. If
PCI and Utopia are both enabled Utopia will operate in single PHY mode only. Boot strapping options are
used to select the state of the Utopia, EMAC and PCI interfaces. Refer to the TCI6482 data manual for
more details.
The Utopia RX and TX clocks are supplied externally and supports clock rates up to 50MHz.
If the Utopia interface is selected, software needs to enable it after reset release before it is accessible.
If the Utopia interface is not enabled, the input pins can be unconnected (floating) but this will result in
some additional power due to leakage. This power can be minimized by adding external pull-ups.
If the Utopia interface is enabled but some inputs are not used, external pull-ups or pull-downs are needed
to put these inputs into valid states.
SPRAAC7B – April 2006
TMS320TCI6482 Design Guide and Migration from TMS320TCI100