OPERATION
8200D 330080 (6--04)
28
CIRCUIT BREAKERS
The circuit breakers are resetable electrical circuit
protection devices. Their design stops the flow of
current in the event of a circuit overload. Once a
circuit breaker is tripped, it must be reset
manually. Press the reset button after the breaker
has cooled down.
If the overload that caused the circuit breaker to
trip is still there, the circuit breaker will continue to
stop current flow until the problem is corrected.
The circuit breakers are located in the operator
compartment.
The chart lists the circuit breakers and the
electrical components they protect.
Circuit
Breaker Rating Circuit Protected
CB-1
15 A
Horn
CB-2
15 A
Ignition
CB-3
15 A
Headlights / Taillights
CB-4
5 A
Logic Power
CB-5
15 A
Sweeping
CB-6
15 A
Scrubbing Accessories
CB-7
15 A
Scrubbing Brushes
CB-8
15 A
Filter Shaker Motor
FUSE
The fuse is a one--time protection device designed
to stop the flow of current in the event of a circuit
overload. Never substitute higher value fuses than
specified.
The fuse is located in the operator compartment.
Remove the circuit breaker panel to gain access
to the fuse.
Fuse
Rating Circuit Protected
FU-1
40 A
Glow plugs