- 82 -
-(3529-(5,7,'$-(6752-=$9$5(1-(8*$â(1,,6./-8ý(1,=6758-1(
05(ä(
15.1 REDOVNO SERVISIRANJE
5$'29(5('2912*6(59,6,5$1-$02ä(,=95â,7,23(5$7(5
15.1.1 PLAMENIK
,]EMHJDYDWLGDVHSODPHQLNLQMHQNDEHOQDVODQMDQDWRSOHGLMHORYHWRELSURX]URþLOR
WDOMHQMHL]RODFLMVNLKPDWHULMDODLRãWHWLOREDWHULMX
3RYUHPHQRSURYMHULWLQHSURSXVQRVWFLMHYLLSOLQVNLKSULNOMXþDND
3DåOMLYR VSRMLWL KYDWDOMNX ]D GUåDQMH HOHNWURGH RVRYLQX ]D GUåDQMH KYDWDOMNH VD
odabranim promjerom elektrode kako bi se izbjeglo pregrijavanje, neispravna
difuzija plina i neispravan rad.
3URYMHULWL SULMH VYDNH XSRWUHEH VWDQMH WURãHQRVWL L LVSUDYQRVW SRVWDYOMDQMD NUDMQMLK
GLMHORYD SODPHQLN SUVNDOLFH HOHNWURGH KYDWDOMNH ]D GUåDQMH HOHNWURGH GLIX]RUD
plina.
8UHÿDM]DQDSDMDQMHåLFRP
ýHVWRSURYMHUDYDWLVWDQMHLVWURãHQRVWLYDOMDND]DSRYODþHQMHåLFHSRYUHPHQRXNORQLWL
PHWDOQXSUDãLQXNRMDVHSRORåLODQDSRGUXþMHYXþHåLFHYDOMFLLYRGLþLåLFHQDXOD]XL
izlazu).
15.2 IZVANREDNO SERVISIRANJE
5$'1-(,=9$15('12*6(59,6,5$1-$02ä(95â,7,,6./-8ý,92,6.8612
,/,.9$/,),&,5$12262%/-((/(.7520(+$1,ý.(6758.(32â7,9$-8û,
7(+1,ý.812508,(&(1
32=25 35,-( 8./$1-$1-$ 2./23$ 6752-$ =$ 9$5(1-( ,
32ý,0$1-$ 5$'29$ 8 8187$51-(0 ',-(/8 6752-$ 3275(%12 -(
3529-(5,7,'$-(6752-8*$â(1,,6./-8ý(1,=6758-1(05(ä(
(YHQWXDOQH SURYMHUH L]YUãHQH SRG QDSRQRP XQXWDU VWURMD ]D YDUHQMH PRJX
SURX]URþLWLWHãNLVWUXMQLXGDUXVOLMHGL]UDYQRJGRGLUDVDGLMHORYLPDSRGQDSRQRP
LLOLR]OMHGHSURX]URþHQHXVOLMHGL]UDYQRJGRGLUDVDGLMHORYLPDXSRNUHWX
3RWUHEQRMHSRYUHPHQRLXVYDNRPVOXþDMXþHVWRRYLVQRRXSRWUHELLSUDãQMDYRVWL
SURVWRUD SURYMHULWL XQXWUDãQMRVW VWURMD L XNORQLWL SUDãLQX NRMD VH SRORåLOD QD
transformator, putem mlaza suhog komprimiranog zraka (max 10 bara).
,]EMHJDYDWL GD VH XSHUL POD] NRPSULPLUDQRJ ]UDND SUHPD HOHNWURQLþNLP
NRPSRQHQWDPDHYHQWXDOQRLKRþLVWLWLYUORPHNDQRPþHWNRPLOLSULNODGQLPUDVWYRUQLP
sredstvima.
7RPSULOLNRPSRWUHEQRMHLSURYMHULWLGDVXHOHNWULþQLSULNOMXþFLSULNODGQR]DWHJQXWLLGD
su kablovi prikladno izolirani.
1DNRQWLKSURYMHUDSRWUHEQRMHSRQRYQRSRVWDYLWLRNORSVWURMDMDNR]DWHåXüLYLMNH
- Potrebno je apsolutno izbjegavati varenje sa otvorenim strojem za varenje.
1DNRQVHUYLVLUDQMDLOLSRSUDYOMDQMDSRQRYQRRVSRVRELWLVSRMHYHLNDEORYHNDRãWRVX
ELOLXSRþHWNXSD]HüLGDLVWLQHGRÿXXGRGLUVDGLMHORYLPDXSRNUHWXLOLVDGLMHORYLPD
NRMLPRJXSRVWLüLYLVRNXWHPSHUDWXUX6SRMLWLWUDNRPVYHVSURYRGQLNHNDRãWRVXELOL
SULMHSD]HüLGDVXVSRMHYLSULPDUQRJWUDQVIRUPDURDSRGYLVRNLPQDSRQRPRGYRMHQL
od spojeva sekundarnih transformatora pod niskim naponom.
8SRWULMHELWLVYHRULJLQDOQHURQGHOHLYLMNH]D]DWYDUHQMHNXþLãWD
16. POTRAGA ZA KVAROVIMA
8 6/8ý$-8 1(,635$912* 5$'$ , 35,-( 95â(1-$ 6,67(0$76.,-,+
3529-(5$ ,/, 35,-( 2%5$û$1-$ 9$â(0 &(158 =$ 6(59,6,5$1-(
PROVJERITI:
'D MH VD RSüRP VNROSNRP QD ´21´ RGJRYDUDMXüD ODPSD XNOMXþHQD X SURWLYQRP
QHSUDYLOQRVWVHQDOD]LLQDþHXOLQLMLQDSDMDQMDNDEORYLXWLNDþLLOLXWLþQLFDRVLJXUDþL
itd.).
- Da nema alarma koji ukazuje na pregrijavanje, nedovoljni napon ili prekomjerni
napon ili kratki spoj.
3URYMHULWL GD VH SRãWLYDR RGQRV QRPLQDOQRJ SUHNLGDQMD X VOXþDMX XNOMXþHQMD
WHUPRVWDWVNH ]DãWLWH SULþHNDWL SULURGQR KODÿHQMH VWURMD SURYMHULWL IXQNFLRQDOQRVW
ventilatora.
- Provjeriti napon linije: ako je vrijednost previsoka ili preniska stroj ostaje blokiran.
3URYMHULWLGDQHPDNUDWNLKVSRMHYDQDL]OD]XVWURMDXWRPVOXþDMXXNORQLWLQHSUDYLOQRVWL
'DVXSULNOMXþFLNUXJDYDUHQMDL]YUãHQLLVSUDYQRDSRVHEQRGDMHKYDWDOMNDNDEHOD
uzemljenja stvarno povezana sa dijelom i bez prisutnosti izolacijskih materijala (npr.
boje).
'DMHXSRWUHEOMHQ]DãWLWQLSOLQLVSUDYDQLXLVSUDYQRMNROLþLQL
Содержание TECHNOMIG 210 DUAL SYNERGIC
Страница 158: ... 158 FIG B2 WELDING POLARITY CHART TORCH WORKPIECE MIG MAG GAS TIG MMA 1 2 3 4 5 6 13 15 14 ...
Страница 159: ... 159 FIG B3 1 4 9 10 5 6 8 2 11 3 12 13 15 14 16 17 ...
Страница 163: ... 163 FIG D2 Nr 8 M6x16 H H H H H O P T I O N A L ...
Страница 164: ... 164 FIG E FIG F TAB 5 FIG G SUGGESTED VALUES FOR WELDING DATI ORIENTATIVI PER SALDATURA ...
Страница 165: ... 165 FIG H d a a ...
Страница 166: ... 166 FIG H1 ...
Страница 167: ... 167 FIG H2 ...
Страница 168: ... 168 FIG I 0 8 0 8 1 2 3 4 5 ...
Страница 169: ... 169 1 2 3 4 FIG L FIG M 1 9 2 3 4 5 6 7 8 ...
Страница 170: ... 170 1 2 FIG N FIG O ...