54
Table 27 I/O High Value
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
9999999
1
I/O#0 property parameter
S32
I/O#0 Low level
Parameter defines low value of triggered I/O property. This parameter is used to set
thresholds for I/O properties to generate events.
Table 28 I/O Low Value
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
9999999
0
I/O#0 property parameter
S32
I/O#0 logic operand
Parameter defines when event is sent: 0 is event on exit, 1 – on entrance, 2 – on both, 3 –
monitoring, 4 – hysteresis, 5 – on change.
Table 29 I/O Logic Operand
Minimal
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
5
2
S8
I/O#0 averaging constant
Parameter defines I/O property sample length to average. If no averaging needed default
value is 1.
Table 30 I/O Averaging constant
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
99999999
1
S32