49
Table 22 CAN elements and parameters
CAN Element
Number
CAN Element
parameters
CAN#0
x406
CAN#1
x407
CAN#2
x408
CAN#3
x409
CAN#4
x410
CAN#5
x411
CAN#6
x412
CAN#7
x413
CAN#8
x414
CAN#9
x415
There are only 14 I/O parameters that could use Averaging Constant:
Digital Inputs (1-4); Analog Inputs (1-4); Battery Voltage; Battery Current;
External Voltage; PDOP; HDOP; Speedometer.
I/O parameters: “Current Profile”, “Fuel level meter” (1-2), “Fuel
temperature” (1-2), “GNSS Status”, “Movement”, “Active GSM Operator”,
“iButton ID”, “Odometer”, “GSM Signal”, “Deep Sleep”, “Cell ID”, “Area
Code”, “PCB Temperature”, “Dallas temperature Sensor 0..2”, “Fuel
Counter” and “RFID ID” cannot use Averaging constant functionality.
6.3.3.5
I/O
If all I/O elements are disabled AVL packet comes with GPS information only. After enabling
I/O element(s) AVL packet in couple with GPS information contains current value(s) of enabled
I/O element.
6.3.3.5.1
FM6320 available I/O list
Table 23 PERMANENT I/O elements list description
Permanent I/O elements
(are always sent (with every record) to server if enabled)
Nr.
Property Name
Bytes
Description
1
Digital Input Status 1
1
Logic: 0 / 1
2
Digital Input Status 2
1
Logic: 0 / 1
3
Digital Input Status 3
1
Logic: 0 / 1
4
Digital Input Status 4
1
Logic: 0 / 1
5
Digital Output Status 1
1
Logic: 0 / 1
6
Digital Output Status 2
1
Logic: 0 / 1
7
Digital Output Status 3
1
Logic: 0 / 1
8
Digital Output Status 4
1
Logic: 0 / 1
9
Analog Input 1
3
Voltage: mV, 0 – 30 V
10
Analog Input 2
3
Voltage: mV, 0 – 30 V
11
Profile
1
Value in scale 1 – 4
12
Battery Voltage
2
Voltage: mV
13
Battery Current
2
Voltage: mA
14
GNSS PDOP
2
Probability * 10; 0-500
15
GNSS HDOP
2
Probability * 10; 0-500