75
8.2.1
Configuration
Data acquisition by I/O elements can be configured selecting I/O menu in configurator
(refer to chapter 6.3.3.5.2).
Priority:
Low – as a regular data; High – generated record are sent immediately to server;
Panic -
generated record are sent immediately to server and simultaneously the same record as
SMS message;
High Level
: High range of value input;
Low Level
: Low Range of value input;
Averaging constant
: (see detailed description in chapter 6.3.3.5.2)
8.2.2
Event generation
There are five record event generation type examples (I/O speed is taken as I/O value
example), please refer to Figures below.
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Time, t
High Level
Low Level
1. On Zone Exit
Figure 47 Event On Zone exit
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Time, t
High Level
Low Level
2. On Zone Entrance
Figure 48 Event On Zone entrance
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Time, t
High Level
Low Level
3. On Both
Figure 49 Event On both
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Time, t
High Level
Low Level
4. Monitoring
Figure 50 Monitoring
Speed,
Km/h
100
20
0
- Event Generated / Record Saved
Time, t
High Level
Low Level
5. Hysterisis
Figure 51 Event on Hysteresis
Содержание FM6320
Страница 1: ...FM6320 User Manual V1 13...